Radial Lead Fuses
TR5® > Fast-Acting Fuse > 370 Series
Electrical Characteristics
Nominal
Cold
Resistance
(Ohms)
Voltage
Drop
1.0×IN
Power
Dissipation
1.5×IN
Melting
Integral
10×IN
Agency Approvals
Amp
Rated Voltage
Breaking
Capacity
Code Current Rating
PS
E
max. (mV) max. (mW) max. (A2s)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0040
0050
0063
0080
0100
0125
0160
0200 200mA
0250 250mA
0315 315mA
0400 400mA
0500 500mA
0630 630mA
0800 800mA
40mA
50mA
63mA
80mA
100mA
125mA
160mA
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
6.0000
4.0224
2.6740
2.0000
4.6100
3.2400
2.2520
1.6900
1.3420
0.9300
0.1610
0.1210
0.0920
0.0760
0.0676
0.0518
0.0420
0.0325
0.0246
0.0184
0.0129
0.0105
0.0073
900
320
350
370
600
550
500
465
400
380
120
120
115
120
110
100
100
85
100
80
0.0002
0.0004
0.0005
0.0014
0.0038
0.0066
0.0140
0.0300
0.0510
0.1000
0.0250
0.0420
0.0760
0.1200
0.2000
0.3100
0.5300
0.9800
1.8000
3.1000
6.7000
12.0000
24.0000
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
100
120
130
172
165
190
250
250
135
155
200
310
310
360
600
500
660
950
920
1000
1200
35A @
250VAC
X
X
X
X
X
X
X
X
1100
1125
1160
1200
1250
1315
1400
1500
1.00A
1.25A
1.60A
2.00A
2.50A
3.15A
4.00A
5.00A
80
90
40A / 250VAC
50A / 250VAC
63A / 250VAC
80
80
1630 6.30A*
70
1
*
Per UL, approved breaking capacity is 50 A at 250 V.
Conducting path min. 0.2 mm2
Notes:
1) 1.00 means the number one with two decimal places. 1,000 means the number one thousand.
2) Resistance is measured at 10% of rated current, 25ºC.
Temperature Re-rating Curve
AverageTime Current Curves
140
120
100
80
100000
10000
1000
100
60
ꢏꢐꢊꢋ
40
20
0
-40
-20
0
20
40
60
80
ꢀꢁꢂꢃꢄꢅꢆ ꢆꢄꢁꢇꢄRꢀꢆꢈRꢄ ꢉꢊꢋꢌ
10
Note
1. Rerating depicted in this curve is in addition to the standard derating of 25% for
continuous operation.
1
0.100
0.010
0.001
0.02
0.100
1
10
100
CURRENT IN AMPERES
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 01/04/16