Low Inductance, High Frequency Chip Inductor
Type 3650 Series
Climatic Test
Item
Specification
Test Method
Operating Temp. Range:
Humidity Resistance:
-40ꢀ° to +125ꢀ°
Temperature: 40 2ꢀ°
Relative Humidity: 90~95%
Time: 96hrs 2hrs
Measured after exposure in the room condition
for 2hrs
Low Temp. Storage Test:
Thermal Shock Test:
Temperature: -40 2ꢀ°
Time: 48 2hrs
Inductors are to be tested after 1 hour at
room temperature
Appearance: No damage
∆L ≤ 10%
One °ycle:
Step
Temperature(ꢀ°)
-25 3
Time (min)
∆Q ≤ 20%
1
30
15
30
15
2
25 2
3
85 3
4
25 2
Total: 5 °ycles
High Temp. Storage Test:
High Temp. Load Life Test:
Humidity Load Life:
Temperature:125 2ꢀ°
Time: 48 2hrs
Measured after 1 hour at room temperature
Temperature:85 2ꢀ°
Time:1000 12hrs
Load: Rated current
There should be no evidence
of short or open circuit.
Temperature: 40 2ꢀ°
Relative Humidity: 90~95%
Time: 1000 12hrs
Load: Rated current
* Storage Temperature: 25 3ꢀ°, <80%RH
Dimensions
Type 3650 Series
A
Max.
B
Max.
C
Max.
D
Ref.
Series
E
F
G
H
I
J
36502°
36502A
36501J
36501E
2.92
2.29
1.80
1.27
2.79
1.73
1.12
0.76
2.10
1.52
1.02
0.61
0.51
0.51
0.38
0.15
2.03
1.27
0.76
0.51
0.51
0.51
0.33
0.23
1.52
1.02
0.86
0.56
2.54
1.78
1.02
0.66
1.02
1.02
0.64
0.50
1.27
0.76
0.64
0.46
Type 3651 Series
A
Series
B
Max.
C
Max.
D
Ref.
E
F
G
H
I
J
Max.
36512°
36512A
2.92
2.29
2.79
1.73
1.40
1.03
0.65
0.51
2.03
1.27
0.51
0.44
1.52
1.02
2.54
1.78
1.02
1.02
1.27
0.76
Type 3652 / 3653 Series
A
Max.
B
Max.
C
Max.
D
Ref.
Series
E
F
G
H
I
J
36532°
36532A
36521J
2.92
2.29
1.80
2.79
1.73
1.12
2.03
1.52
1.02
0.65
0.51
0.38
2.03
1.27
0.76
0.51
0.44
0.33
1.52
1.02
0.86
2.54
1.78
1.02
1.02
1.02
0.64
1.27
0.76
0.64
Literature No. 1773163
Issued: 12-05
Dimensions are shown for
reference purposes only.
Dimensions are in millimetres Specifications subject to
unless otherwise specified. change.
www.tycoelectronics.com