35ACPO_S Series
35W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
AC-DC Converter
35 Watt
High efficiency up to 86%
Universal AC input range
(90~264VAC)
Over power protection (OPP)
Over voltage protection (OVP)
Over load protection (OLP)
Short circuit protection (SCP)
Wide operating ambient
temperature (-20°C~65°C)
All using 105°C long life
electrolytic capacitors
The 35ACPO_S series features standard rail mounting, energy efficiency
and is highly cost-effective. The series offers stability and high noise
immunity especially for industrial control equipment, machinery and
other demanding environments for industrial equipment. This converter
offers a compact and light weight design with and standard rail installati-
on (35mm). Furthermore this series offers Easy Fuse Tripping due and a
built-in DC OK relay contact. The converter can be installed on TS-35/7.5
or TS-35/15.
100% full load burn-in test
UL-60950-1 (E347551)
Common specifications
Short circut protection:
Temperature rise at full load:
Cooling:
Input specifications
Long-term mode, automatic recovery
50°C MAX
Input voltage range
Input frequency
AC current
90~264VAC
47~63Hz
230VAC
1A (max)
Free air convection
-20°C~+65°C
Inrush current
Cold start
@115VAC
23A (typ)
@230VAC
45A (typ)
Operation temperature range:
Storage temperature range:
Storage humidity range:
Temperature coefficient:
MTBF (using MIL-HDBK-217F):
Safety standards:
-30°C ~+85°C
Leakage current
Input—output: <0.25mA
Input—PG: <3.5mA
< 95%
0.03%/°C MAX
+25°C >200,000 hours
UL60950-1; EN60950-1: 2006
Output specifications
Item
Test conditions
Full load
Min Typ
1
Max
Units
%
Case material:
Heat-resistant Plastic (UL94-V0) and
metal
Output voltage
accuracy
Dimensions (L*W*H):
Weight:
101.6×50.8×24mm
183.3g
Voltage adjustment • 5V
4.75
11.4
22.8
45.6
5.5
V
range
• 12V
• 24V
• 48V
13.2
26.4
52.8
Line regulation
Load regulation
Vin= min. to max. at
full load
0.5
%
%
Isolation specifications
Item
Test condition
Min
Typ
Max
Units
VAC
0% to 100% load
1
Withstand voltage*
• Input-output.: 10mA
• Output-PG: 10mA
• Output-PG: 10mA
3000
1500
500
Set-up time
(full load)
• @230VAC input
• @115VAC input
1
2
s
s
Hold-up time
(full load)
• @230VAC input
• @115VAC input
20
10
ms
ms
Isolation resistance
100
MΩ
* Input-Output, tested for 1 minute, 500VDC and leakage current less than 1mA
Overshoot and
undershoot
5
%
Switching frequency
65
KHz
Protection specifications
* Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated
with a 0.1 uF & 10uF parallel capacitor.
Over-load
protection
• 5V: 6.3~10.8A
• 12V: 3.15~5.4A
• 24V: 1.58~2.7A
• 48V: 0.78~1.35A
Protection type:
Hiccup model, auto recovery
Example:
35ACPO_24S
Over-voltage
protection
• 5V: 5.75~7.5V
Protection type:
Constant voltage, auto
recovery
• 12V: 13.8~16.2V
• 24V: 27.6~32.4V
• 48V: 55.2~64.8V
35 = 35Watt
AC = AC-DC
PO = series
24 = 24 Vout
S = single output
Over-power
protection
• 5V: 31.5~54W
Protection type:
Hiccup model, auto recovery
• 12V: 37.8~64.8W
• 24V: 37.9~64.8W
• 48V: 37.4~64.8W
Note:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated
load and 25°C of ambient temperature.
Page 1 of 3
35ACPO_S – Rev. 2020-1.1
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com