Max. 102 m3/h
DC axial fans
92 x 25 mm
–
Possible special versions:
(See chapter DC fans - specials)
- Speed signal
–
Material:
Housing: GRP1) (PBT)
Impeller: GRP1) (PA)
–
–
Direction of air flow: Exhaust over struts
Direction of rotation: Counterclockwise,
looking towards rotor
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
–
–
Connection:
Via single wires AWG 24,
TR 64
100 g
Weight:
- Analog control input
- Moisture protection
- Degree of protection: IP 54 / IP 68
1) Fiberglass-reinforced plastic
Series 3400 N
Nominal data
Type
m3/h
cfm
VDC
VDC
dB(A) Bel(A)
/
Watts
rpm-1
°C
Hours
Hours
¿
¿
¡
¡
¬
¬
√
√
ƒ
ƒ
ƒ
3412 NGLE
3412 NLE
3412 NGME
3412 NME
3412 NG
61
61
35.9
35.9
42.4
42.4
49.4
49.4
55.3
55.3
60.0
60.0
60.0
12
12
12
12
12
12
12
12
12
12
12
8...15
8...15
8...15
8...15
8...15
8...15
8...15
8...15
8...13.2
8...13.2
8...15
23
23
28
28
32
32
36
36
39
39
39
4.0
4.0
4.3
4.3
4.7
4.7
5.0
5.0
5.1
5.1
5.1
1.1
0.8
1.6
1.1
1.9
1.7
2.3
2.1
3.2
2.9
2.7
1 950
1 950
2 300
2 300
2 700
2 700
3 000
3 000
3 250
3 250
3 250
-20...+80
-20...+85
-20...+75
-20...+75
-20...+70
-20...+70
-20...+70
-20...+70
-20...+60
-20...+60
-20...+70
80 000 / 22 500 135 000
80 000 / 17 500 135 000
75 000 / 27 500 127 500
75 000 / 27 500 127 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 45 000 117 500
70 000 / 45 000 117 500
70 000 / 35 000 117 500
72
72
84
3412 N
84
3412 NGH
3412 NH
94
94
3412 NGHH
3412 NHH
3412 NHH-379
102
102
102
¿
¿
¡
¡
¬
¬
√
√
ƒ
ƒ
ƒ
ƒ
3414 NGL
3414 NL
61
61
35.9
35.9
42.4
42.4
49.4
49.4
55.3
55.3
60.0
60.0
60.0
60.0
24
24
24
24
24
24
24
24
24
24
24
24
18...28
18...28
18...28
18...28
18...28
18...28
18...26
18...26
18...26
18...28
18...26
18...28
23
23
28
28
32
32
36
36
39
39
39
39
4.0
4.0
4.3
4.3
4.7
4.7
5.0
5.0
5.1
5.1
5.1
5.1
1.4
1.1
1.7
1.4
2.5
2.1
3.0
2.3
3.2
3.2
3.1
3.2
1 950
1 950
2 300
2 300
2 700
2 700
3 000
3 000
3 250
3 250
3 250
3 250
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
-20...+70
80 000 / 40 000 135 000
80 000 / 40 000 135 000
75 000 / 37 500 127 500
75 000 / 37 500 127 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
70 000 / 35 000 117 500
3414 NGM
3414 NM
72
72
3414 NG
84
3414 N
84
3414 NGH
3414 NH
94
94
3414 NGHH
3414 NGHH-389
3414 NHH
3414 NHH-386
102
102
102
102
¬
3418 N
84
49.4
48
36...56
32
4.7
2.4
2 700
-20...+70
70 000 / 35 000 117 500
Other 48 VDC models on request.
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L A ISO 103002
W
measured on a hemisphere with a radius of 2 m.
Sound pressure level L A measured at 1 m distance
p
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Finger guards
from p. 242
48