Max. 280 m3/h
DC axial fans
92 x 38 mm
–
Possible special versions:
(See chapter DC fans - specials)
- Speed signal
–
Material:
Housing: GRP1) (PBT)
Impeller: GRP1) (PA)
–
–
Direction of air flow: Exhaust over struts
Direction of rotation: Clockwise,
looking towards rotor
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
–
–
Connection:
Via single wires AWG 24
(H3 and H4: AWG 22), TR 64
240 g (H3 and H4: 280 g)
Weight:
- Analog control input
- Moisture protection
- Degree of protection: IP 54 / IP 68
1) Fiberglass-reinforced plastic
Series 3200 J
Nominal data
Type
m3/h
cfm
VDC
VDC
dB(A) Bel(A)
/
Watts
rpm-1
°C
Hours
Hours
3212 JN
3212 JH
3212 JH3
3212 JH4
130
146
237
280
76.5
86.0
12
12
12
12
7...13.8
7...15
51
55
69
73
6.1
6.4
7.8
8.2
7.5
9.0
6 000
6 800
-20 ...+70
-20 ...+70
-20 ...+70
-20 ...+70
70 000 / 35 000 117 500
70 000 / 35 000 117 500
65 000 / 32 500 110 000
60 000 / 30 000 110 000
¿
¡
¬
√
139.5
164.8
6...13.8
6...13.8
31.0* 11 000
50.0* 13 000
3214 JN
3214 JH
3214 JH3
3214 JH4
130
146
237
280
76.5
86.0
24
24
24
24
11...28
51
55
69
73
6.1
6.4
7.8
8.2
6.5
9.0
6 000
6 800
-20 ...+70
-20 ...+70
-20 ...+70
-20 ...+70
70 000 / 35 000 117 500
70 000 / 35 000 117 500
65 000 / 32 500 110 000
60 000 / 30 000 110 000
¿
¡
¬
√
12...30
139.5
164.8
12...27.6
12...27.6
30.0* 11 000
50.0* 13 000
3218 JN
3218 JH
3218 JH3
130
146
237
280
76.5
86.0
48
48
48
48
36...56
51
55
69
73
6.1
6.4
7.8
8.2
7.0
9.5
6 000
6 800
-20 ...+70
-20 ...+70
-20 ...+70
-20 ...+70
70 000 / 35 000 117 500
70 000 / 35 000 117 500
65 000 / 32 500 110 000
60 000 / 30 000 110 000
¿
¡
¬
√
36...53
139.5
164.8
20...58.0
20...58.0
29.0* 11 000
50.0* 13 000
3218 JH4
Subject to change
3200 JH3 and JH4 also available as standard with PWM control input and speed signal.
Speed control range from 2000 rpm-1 up to maximum nominal speed. Standstill at 0% PWM, maximum speed if control cable is interrupted.
* Power consumption at free air flow. These values can be significantly higher in the operating point.
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L A ISO 103002
W
measured on a hemisphere with a radius of 2 m.
Sound pressure level L A measured at 1 m distance
p
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Finger guards
from p. 242
51