440L, 30LV, 30LVS, 25Y, 125L, 20VL Series
Vishay Cera-Mite
AC Line Rated Disc Capacitors
X & Y EMI/RFI FILTER TYPES: ACROSS-THE-LINE,
LINE-BY-PASS, ANTENNA COUPLING
Vishay Cera-Mite AC Line Rated Discs are rugged, high voltage capacitors specifically designed and tested
for use on 125 Volt through 600 Volt AC power sources. Certified to meet demanding X & Y type worldwide
safety agency requirements, they are applied in across-the-line, line-to-ground, and line-by-pass
filtering applications. Vishay Cera-Mite offers the most
complete selection in the industry—six product families—
exactly tailored to your needs.
AC LINE RATED CERAMIC CAPACITOR SPECIFICATIONS
PERFORMANCE DATA / SERIES: 440L 30LV 30LVS 25Y 125L 20VL
• Worldwide Safety Agency Recognition
- Underwriters Laboratories - UL1414 & UL1283
Application Voltage Range
(Vrms 50/60 Hz) (Note 1)
Dielectric Strength
250/500 300/400 250/400 250/400 250
250
- Canadian Standards Association - CSA 22.2 No. 1 & No. 8
- European EN132400 to IEC 384-14 Second Edition
• Required In AC Power Supply and Filter Applications
• Six Families Tailored To Specific Industry Requirements
• Complete Range of Capacitance Values
4000 2500 2500 2500 2000 1250
(Vrms 50/60 HZ for 1 minute)
Dissipation Factor (Maximum)
Insulation Resistance (Minimum)
Mechanical Data
2%
1000 ΩF
Service Temperature 125°C Maximum;
Coating Material per UL94V0
Temperature Characteristics
Y5U
Y5U Y5U
Y5S Y5V Y5V
See Part Number Detail for Temperature Characteristics
SAFETY AGENCY RECOGNITION AND EMI/RFI FILTERING SUBCLASS
Series / Recognition / Voltage
Underwriters Laboratories Inc.: (Note 2)
UL 1414 Across-The-Line
440L
30LV
30LVS
25Y
125L
20VL
Across-The-Line Across-The-Line
Antenna-Coupling Antenna-Coupling
—
—
—
—
—
—
—
—
UL 1414 Antenna Coupling
—
Line-By-Pass
250 VAC
—
UL 1414 Line-By-Pass
UL 1414 Rated Voltage
Electromagnetic Interference Filters
UL1283 Rated Voltage
Line-By-Pass
250 VAC
EMI Filters
600 VAC
Line-By-Pass
250 VAC
EMI Filters
250 VAC
Line-By-Pass
250 VAC
EMI Filters
250 VAC
Line-By-Pass
250 VAC
EMI Filters
250 VAC
—
EMI Filters
250 VAC
—
Canadian Standards Association:
CSA 22.2 No.1 Across-The-Line
CSA 22.2 No.1 Isolation
CSA 22.2 No. 1 Rated Voltage
CSA 22.2 No. 8 Line-to-Ground Capacitors
For Use in Certified EMI Filters
CSA 22.2 No. 8 Rated Voltage
Across-The-Line Across-The-Line
—
Isolation
250 VAC
—
Isolation
250 VAC
—
Isolation
125/250 VAC
—
—
—
Isolation
250 VAC
Isolation
250 VAC
—
—
—
Line-To-Ground
Certified EMI Filters Certified EMI Filters Certified EMI Filters
400 VAC 400 VAC 400 VAC
Line-To-Ground
Line-To-Ground
—
—
—
Line-To-Ground
Certified EMI Filters
250 VAC
European CENELEC Electronic Components Committee (CECC) EN 132 400 to Publication IEC 384-14 Table II, Edition 2:
IEC 384-14 Second Edition Subclass Y: (Note 3)
Subclass Y Voltage (Vrms 50-60 Hz)
Type of Insulation Bridged
Y1
500 VAC
Double or
Reinforced
8 kV
Y2
300 VAC
Basic or
Supplementary
5 kV
Y2
250 VAC
Basic or
Supplementary
5 kV
Y2
250 VAC
Basic or
Y4
125 VAC
Basic or
—
—
Supplementary Supplementary
Peak Impulse Voltage Before Endurance Test
IEC 384-14 Second Edition Subclass X: (Note 4)
Subclass X Voltage (Vrms 50-60 Hz)
Peak Impulse Voltage in Service
5 kV
X1
400 VAC
2.5 to 4.0 kV
High Pulse
2.5 kV
X1
400 VAC
2.5 to 4.0 kV
High Pulse
—
X2
X1
X1
X1
400 VAC
2.5 to 4.0 kV
High Pulse
400 VAC
2.5 to 4.0 kV
High Pulse
400 VAC
2.5 to 4.0 kV
High Pulse
400 VAC
To 2.5 kV
Gen. Purpose
Application
Damp Heat, Steady State Recognition
Code HKF - 25°C/ + 125°C/21 days
Note 1
Note 3
• Class X capacitors are divided into subclasses
according to the peak impulse test voltage
superimposed on the main voltage
Voltage Ratings: All ratings are manufacturer’s
rating.
IEC 384-14 Subclass Y Capacitors:
•
•
•
•
A capacitor of a type suitable for use in situations
where failure of the capacitor could lead to
danger of electric shock.
ClassY capacitors are divided into sub- classes
based on type of insulation bridged and voltage
ranges.
For definitions of basic, supplementary,
double and reinforced insulation, see IEC
Publication 536.
•
Part markings are governed by agency
rules and customer requirements.
Parts are marked 250 VAC unless otherwise
requested.
Note 5
AC Leakage Current:
• For all Series (except 125L) - AC Leakage
Current (mA) specified at 250 Vrms, 60 Hz.
•
Note 2
• For 125L Series
- AC Leakage Current
UL1414 Across-The-Line, Antenna Coupling, and
Line-By-Pass Capacitors:
(mA) specified at 125 Vrms, 60Hz.
Subclass
Y capacitors may be used in
•
Across-The-Line—A capacitor connected
either across a supply circuit or between
one side of a supply circuit and a conductive
part that may be connected to earth ground.
Antenna-Coupling—A capacitor connected
from an antenna terminal to circuits within an
appliance.
Line-By-Pass—A capacitor connected between
one side of a supply circuit and an accessible
conductive part.
Note 6
applications which require
X rating.
a Subclass
Alternate Lead Spacings of 7.5mm and 10mm
are available bulk or tape & reel.
• European Required Minimum Lead Clearance
(Prevents Use of Inside Crimp) .315" (8mm) on
440L Series; 0.118" (3mm) on all other series.
Note 4
•
•
IEC 384-14 Subclass X Capacitors:
•
A capacitor of a type suitable for use
in situations where failure of the capacitor
would not lead to danger of electric
shock.
www.vishay.com
20
Document Number: 23092
Revision 14-May-02