General Purpose
Panel/Plug-in Relays
Potter & Brumfield
PRD Series Power Relay
n
n
n
n
n
Contact ratings to 50A
Magnetic blowouts available for switching DC loads
Contact arrangement up to 2 form C (2CO)
1 form C auxiliary switch available
UL class B insulation
Typical applications
Industrial controls, lighting.
Approvals
Contact ratings (continued)
UL E22575; CSA LR15734; VDE 40020133 (available only on PRD with DC
coil and Termination code 1)
Type
Load
Cycles
UL 5081)
Models with all screw terminals are UL Listed. Others are UL Recognized.
Technical data of approved types on request.
Models with screws or quick connects for main terminals
Code F, AgCdO, 1 pole
50A, 240VAC, general purpose2)
30A, 277VAC, resistive
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Code F, AgCdO, 2 pole
50A, 240VAC, general purpose2)
30A, 240VAC
20x103
100x103
100x103
100x103
100x103
Contact Data
Contact arrangement
1 and 2 form A (NO); 1 and 2 form C (CO);
1 form X (NO-DM)
600VAC,125VDC
50A
Ag, AgCdO, W
1A, 12VDC or 12VAC
75mΩ max.
75mV
Rated voltage
Rated current
Contact material
Min. recommended contact load
Initial contact resistance
Initial voltage drop
Frequency of operation
Operate/releases time max.
Bounce time max.
20x103
100x103
100x103
100x103
100x103
100x103
20A, 277VAC
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
7200 ops/hr
40/20ms
10ms
2) In order to achieve 50A rating with contact code F, termination Code 0 or A is required.
Code H, Ag with magnetic blowout, 1 or 2 pole
Contact ratings
20A, 125VDC
1/3HP, 125VDC
100x103
100x103
Type
Load
Cycles
UL 5081)
Code J, AgCdO with magnetic blowout, 1 or 2 pole
20A, 125VDC
1/3HP, 125VDC
Code N, W stationary with AgCdO movable, 1 or 2 pole
25A, 250VAC
Models with screws or quick connects for main terminals
Code Y, Ag, 1 pole
25A, 277VAC
100x103
100x103
100x103
100x103
100x103
100x103
100x103
1HP, 120VAC
2HP, 250VAC
10A, 600VAC
100x103
100x103
100x103
1HP, 125VAC
2HP, 250VAC
7A, 50VDC, resistive
Code Y, Ag, 2 pole
25A, 240VAC
UL 5081)
100x103
100x103
100x103
100x103
100x103
100x103
Models with box lugs for main terminals
Code P, Ag, 1 form X
20A, 277VAC
1HP, 120VAC
2HP, 250VAC
7A, 50VDC, resistive
10A, 600VAC
50A, 277VAC, general purpose
30A, 277VAC, ballast
15A, 277VAC, tungsten
102LRA, 17FLA, 240VAC
120LRA, 20FLA, 120VAC
1.5HP, 120VAC
100x103
6x103
6x103
30x103
30x103
30x103
30x103
Code G, AgCdO, 1 pole
30A, 277VAC, resistive
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Code G, AgCdO, 2 pole
30A, 240VAC
100x103
100x103
100x103
100x103
3HP, 240VAC
Factory ratings
Models with box lugs for main terminals
Code R, Ag with magnetic blowout, 1 form X
60A, 28VDC, resistive
100x103
100x103
100x103
100x103
100x103
100x103
100x103
30A, 125VDC
20A, 277VAC
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Mechanical endurance
DC Coil, 1x106 ops.; AC Coil 5x105 ops.
1) Any PRD relay deviating electrically or physically from the standard models in the table is
not UL or CSA listed. All horsepower ratings are for single phase motors..
Auxiliary Snap-Action Switch Contact Data
Contact arrangement
Rating
1 form C (CO)
5A, 120VAC, 60Hz., 25°C
Ag
Contact material
1
06-2016, Rev. 0616
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.