描述
Electronic Reversing-Load Relay for 3-Phase Networks

2964186 数据手册

 浏览型号2964186的Datasheet PDF文件第2页浏览型号2964186的Datasheet PDF文件第3页浏览型号2964186的Datasheet PDF文件第4页浏览型号2964186的Datasheet PDF文件第5页 
ELR W 3/9-400  
ELR W 3/9-500  
Electronic Reversing-Load Relay  
for 3-Phase Networks  
Data Sheet  
01/2005  
Features  
Electronic Reversing-Load Relay  
ELR W 3/9...  
ELR W 3/9... electronic reversing-load relays are the  
practical and user-friendly further development of  
electronic load relays for 3-phase networks.  
The ELR W 3/9... is the fully electronic alternative to  
mechanical contactors. It features a compact design  
and low control power. A further advantage is the high-  
quality, safe screw connection technology.  
These components feature high switching  
frequencies, virtually unlimited service life, no spark  
interference, and completely silent switching at zero  
voltage crossing. The compact, DIN rail-mountable  
modules meet all the requirements of an electronic  
reversing contactor circuit that has been designed  
specifically for industrial applications. Both the  
interlocking of control inputs and the complete wiring  
of the load contacts are incorporated in the device.  
Costly locking switches and contact wiring are thus a  
thing of the past.  
In accordance with DIN VDE 0110 and  
DIN VDE 0636, a conductor cross section  
of 1.5 mm2 (16 AWG), which must be  
fitted with one fuse each (10 A slow-blow  
as mains protection), is required to  
connect the electronic load relay to the  
3-phase network.  
Cabling has been reduced to an absolute minimum.  
Only the following must be applied:  
Control voltage, supply voltage  
input and output  
3-phase load  
The status is clearly indicated by separate LEDs for  
"right rotation", "left rotation", "operating voltage" or  
"impermissible control".  
A short circuit between two phases at the moment of  
switching is prevented by the integrated delay  
between the control pulse and the load control.  
RCV protective circuits on the output side reduce  
voltage peaks that occur in the load circuit to a safe  
level and prevent damage to the output electronics.  
5104778_03_en  
1

与2964186相关器件

型号 品牌 获取价格 描述 数据表
2-964273-1 TE

获取价格

THIS DRAWING IS A CONTROLLED DOCUMENT.
2-964280-1 TE

获取价格

THIS DRAWING IS A CONTROLLED DOCUMENT.
2-964282-1 TE

获取价格

THIS DRAWING IS A CONTROLLED DOCUMENT.
2-964284-1 TE

获取价格

THIS DRAWING IS A CONTROLLED DOCUMENT.
2-964286-1 TE

获取价格

THIS DRAWING IS A CONTROLLED DOCUMENT.
2964322 PHOENIX

获取价格

POWER OPTOCOUPLER 24VDC
2964416 PHOENIX

获取价格

Relays/Accessories
2964445 PHOENIX

获取价格

RELAY MODULE DIN RAIL 1PDT 120V
2964636 PHOENIX

获取价格

Modular Terminal Block,
2964649 PHOENIX

获取价格

POWER OPTOCOUPLER 24VDC