5秒后页面跳转
2036-25-B3 PDF预览

2036-25-B3

更新时间: 2024-11-20 12:29:19
品牌 Logo 应用领域
伯恩斯 - BOURNS 电信集成电路电信电路电信保护电路
页数 文件大小 规格书
3页 531K
描述
2036 Series - Miniature 3-Pole Gas Discharge Tube

2036-25-B3 技术参数

是否Rohs认证:不符合生命周期:Active
零件包装代码:MODULE包装说明:,
针数:3Reach Compliance Code:not_compliant
HTS代码:8542.39.00.01Factory Lead Time:6 weeks
风险等级:5.21Is Samacsys:N
JESD-30 代码:O-XXSS-P3JESD-609代码:e0
湿度敏感等级:1功能数量:1
端子数量:3最高工作温度:85 °C
最低工作温度:-55 °C封装主体材料:UNSPECIFIED
封装形状:ROUND封装形式:SPECIAL SHAPE
认证状态:Not Qualified表面贴装:NO
电信集成电路类型:SURGE PROTECTION CIRCUIT温度等级:OTHER
端子面层:Tin/Lead (Sn90Pb10)端子形式:PIN/PEG
端子位置:UNSPECIFIEDBase Number Matches:1

2036-25-B3 数据手册

 浏览型号2036-25-B3的Datasheet PDF文件第2页浏览型号2036-25-B3的Datasheet PDF文件第3页 
Features  
Applications  
Balanced Mini-TRIGARD™  
5 mm diameter, 7.5 mm long  
UL Recognized  
Telecommunications  
Industrial electronics  
Commercial electronics  
Consumer electronics  
Automotive, aircraft, military electronics  
RoHS compliant* versions available  
2036 Series - Miniature 3-Pole Gas Discharge Tube  
Characteristics  
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31  
Model No.  
Characteristic  
2036-07  
2036-09  
2036-15  
2036-20  
2036-23  
2036-25  
DC Sparkover 2ꢀ ꢁ @ 1ꢀꢀ V/s  
75 V  
9ꢀ V  
15ꢀ V  
2ꢀꢀ V  
23ꢀ V  
25ꢀV  
Impulse Sparkover  
1ꢀꢀ V/µs  
25ꢀ V  
525 V  
25ꢀ V  
55ꢀ V  
35ꢀ V  
5ꢀꢀ V  
425 V  
575 V  
45ꢀ V  
6ꢀꢀ V  
475 V  
625 V  
1ꢀꢀꢀ V/µs  
Model No.  
Characteristic  
2036-30  
2036-35  
2036-40  
2036-42  
2036-47  
2036-60  
DC Sparkover 2ꢀ ꢁ @ 1ꢀꢀ V/s  
3ꢀꢀ V  
35ꢀ V  
4ꢀꢀ V  
42ꢀ V  
47ꢀ V  
6ꢀꢀ V  
Impulse Sparkover  
1ꢀꢀ V/µs  
5ꢀꢀ V  
65ꢀ V  
6ꢀꢀ V  
75ꢀ V  
65ꢀ V  
825 V  
675 V  
85ꢀ V  
75ꢀ V  
95ꢀ V  
85ꢀ V  
1ꢀꢀꢀ V/µs  
11ꢀꢀ V  
Impulse Transverse Delay..................1ꢀꢀ V/µs................................................................................. <75 ns  
1ꢀ  
Insulation Resistance .........................1ꢀꢀ V (5ꢀ V for Model 2ꢀ36–ꢀ7 & 2ꢀ36-ꢀ9)........................... >1ꢀ  
Glow Voltage ......................................1ꢀ mA..................................................................................... ~7ꢀ V  
Arc Voltage.........................................1 A .......................................................................................... ~1ꢀ V  
Glow-Arc Transition Current............................................................................................................... <.5 A  
Capacitance........................................1 MHz..................................................................................... <2 pF  
Ω
1
DC Holdover Voltage .......................135 V, (52 V for Model 2ꢀ36-ꢀ7 & 2ꢀ36-ꢀ9,........................... <15ꢀ ms  
8ꢀ V for Model 2ꢀ36-15)  
2
Impulse Discharge Current.................2ꢀꢀꢀꢀ A, 8/2ꢀ µs ................................................................... 1 operation minimum  
1ꢀꢀꢀꢀ A, 8/2ꢀ µs .................................................................... >1ꢀ operations  
2ꢀꢀꢀ A, 1ꢀ/35ꢀ µs .................................................................. 1 operation  
2ꢀꢀ A, 1ꢀ/1ꢀꢀꢀ µs ................................................................. >3ꢀꢀ operations  
2ꢀꢀ A, 1ꢀ/7ꢀꢀ µs ................................................................... >5ꢀꢀ operations  
2
Alternating Discharge Current............2ꢀ Arms, 1 s .......................................................................... 1 operation minimum  
1ꢀ Arms, 1 s ........................................................................... >1ꢀ operations  
Operating Temperature....................................................................................................................... -55 to +85 °C  
Climatic Category (IEC 6ꢀꢀ68-1)........................................................................................................ 4ꢀ/9ꢀ/21  
Optional Switch-Grade Fail-Short device available.  
Notes:  
UL recognized component, UL File E153537.  
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. ꢀ2ꢀ9 4ꢀꢀV).  
• The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to  
ground.  
8
• Sparkover limits after life 25 ꢁ, IR >1ꢀ Ω (-25 ꢁ,+3ꢀ ꢁ for Model 2ꢀ36-ꢀ7, 2ꢀ36-ꢀ9 and 2ꢀ36-6ꢀ).  
• Operating characteristics per RUS PE-8ꢀ and Telcordia GR 1361 available, contact factory.  
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.  
• At delivery AQL ꢀ.65 Level II, DIN ISO 2859.  
1
2
Network applied.  
DC Sparkover may exceed 25 ꢁ after discharge, but will continue to protect without venting.  
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.  

2036-25-B3 替代型号

型号 品牌 替代类型 描述 数据表
2036-25-B3LF BOURNS

完全替代

Surge Protection Circuit, ROHS COMPLIANT, PACKAGE-3

与2036-25-B3相关器件

型号 品牌 获取价格 描述 数据表
2036-25B3F BOURNS

获取价格

Surge Protection Circuit,
2036-25-B3F BOURNS

获取价格

Surge Protection Circuit,
2036-25-B3FLF BOURNS

获取价格

Surge Protection Circuit, ROHS COMPLIANT PACKAGE
2036-25B3LF BOURNS

获取价格

TELECOM, SURGE PROTECTION CIRCUIT, XSS3, ROHS COMPLIANT PACKAGE
2036-25-B3LF BOURNS

获取价格

Surge Protection Circuit, ROHS COMPLIANT, PACKAGE-3
2036-25B8F BOURNS

获取价格

Surge Protection Circuit,
2036-25-B8F BOURNS

获取价格

TELECOM, SURGE PROTECTION CIRCUIT
2036-25B8FLF BOURNS

获取价格

Surge Protection Circuit, ROHS COMPLIANT PACKAGE
2036-25-B8FLF BOURNS

获取价格

TELECOM, SURGE PROTECTION CIRCUIT, XSS3, ROHS COMPLIANT, PACKAGE-3
2036-25B9 BOURNS

获取价格

TELECOM, SURGE PROTECTION CIRCUIT, XSS3