Features  
Low peak clamping voltage even during  
Cable shields are passed through and  
may be either grounded or arc-protected to  
ground  
Vibration-resistant screw-type clamp  
terminals  
severe current surges  
Ability to repeatedly protect against high  
surge currents up to rated limits  
Convenient mounting and grounding to any  
flat surface or to DIN-1 (TS-32) or DIN-3  
(TS-35) rail  
Flame-resistant epoxy-filled housing  
1840 Series – Signal and Dataline Protector  
®
The Bourns 1840 Series Signal and Dataline Protectors are designed to protect sensitive electronic circuits and components from damaging  
surge voltages and currents. Their extremely fast response and low clamping voltages make them particularly suitable for the protection of sensi-  
tive signal and datalines associated with computer, data communication, instrumentation, broadcasting and industrial controls. They may be used  
directly with EIA standard interfaces RS-232, RS-422, RS-423, RS-485 and with 4-20 mA and 50 mA instrumentation loops. The Model 1840  
Series Signal and Dataline Protectors are fast, rugged and capable of protecting against fast rising voltage transients as well as the severe  
current surges associated with lightning discharges, in each case up to rated limits.  
Method of Operation  
®
The Bourns 1840 Series are heavy-duty, multi-staged protectors. A solid-state 3rd stage protection component intercepts the leading edge of the  
surge within sub-nanosecond response time. Within microseconds, a primary stage 3-electrode common chambered heavy-duty gas discharge  
tube capable of handling 20,000 ampere lightning currents operates and crowbars the majority of the surge energy to ground. The Model 1840  
®
also utilizes Bourns TBU High-Speed Protector (HSP) technology as a key 2nd stage. Any current through the protector exceeding 300 mA  
®
will cause the TBU HSP to quickly transition into a high impedance state, thus isolating any harmful voltage and/or current from damaging the  
protected equipment. The gas discharge tube protector remains in the crowbar state until the surge has passed and line voltages return to safe  
®
levels. The TBU HSP then automatically restores the line to normal operation by resetting to a low impedance state. There is no need for  
resetting a breaker or replacing a fuse to address a transient surge event.  
Application  
Protectors are generally placed at each end of a signal, dataline or current loop. In the case of daisy-chain configurations (such as RS-485),  
protectors are placed at each node.  
®
Related Bourns Protectors  
®
For outdoor applications with 1/2-inch NPT ports (such as field-mounted 4-20 mA transmitters), please refer to the Bourns Model 1669 Series  
Protector. In this application, the mixed use of a Model 1840 Series Protector at the controller and a Model 1669 Series Protector at the field is  
recommended.  
Characteristics @ 25 °C  
Standard Model  
Circuit Diagram  
TBU® DEVICE  
L1  
E1  
1840-05  
1840-12  
1840-24  
SOLID-STATE  
LOW  
VOLTAGE  
PROTECTION  
Maximum Breakdown Voltage  
8 V  
15 V  
30 V  
(L-L) and (L-G)  
TBU® DEVICE  
L2  
E2  
E3  
SHIELD  
SHIELD  
Surge Life  
SHORTING  
LINK  
100 Amps 10 x 1000 μsec............................................ 300 operations min.  
100 Amps 10 x 1000 μsec............................................ 300 operations min.  
500 Amps 10 x 1000 μsec............................................ 50 operations min.  
1000 Amps 10 x 1000 μsec.......................................... 10 operations min.  
3 kA, 6 kV / 8 x 20 μsec Combination Wave................ 100 operations min.  
10 kA / 8 x 20 μsec....................................................... 10 operations min.  
20 kA / 8 x 20 μsec....................................................... 5 operations min.  
Breakdown Voltage............................................................ See table*  
ESD @ 8 kV ...................................................................... 10 operations min.  
Shield ARC Protection 6 kV / 3 kA..................................... 5 operations min.  
Capacitance @ 1 MHz ...................................................... L/G: 45 pF, L/L: 35 pF  
Series Resistance.............................................................. 12 Ω typical  
Maximum Load Continuous Current.................................. 220 mA  
DC Leakage Current at Rated L/G Voltage....................... < 10 μA  
Blocking Current................................................................ 300 mA; typical 450 mA  
Signal/Data Attenuation..................................................... 3 db @ 30 MHz with 50 Ω  
termination  
Asia-Pacific:  
Tel: +886-2 2562-4117  
Fax: +886-2 2562-4116  
EMEA:  
Tel: +36 88 520 390  
Fax: +36 88 520 211  
Operating Temperature...................................................... -40 ºC to +60 ºC  
Response Time.................................................................. < 1 μsec  
Wire Size ........................................................................... 20 AWG  
The Americas:  
Tel: +1-951 781-5500  
Fax: +1-951 781-5700  
*Custom voltages are available upon request. Please visit www.bourns.com/data/global/  
pdfs/SMBJ.pdf for custom allowable voltage. Lead-time may be extended for some custom  
voltages.  
www.bourns.com  
Specifications are subject to change without notice.  
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.  
Users should verify actual device performance in their specific applications.  

与1840-05-A1相关器件

型号 品牌 获取价格 描述 数据表
1840-05-A3 BOURNS

获取价格

Signal and Dataline Protector
1840-05AK10M ETC

获取价格

Industrial Control IC
1840-05AK10R ETC

获取价格

Industrial Control IC
1840-05AK11M ETC

获取价格

Industrial Control IC
1840-05AK11R ETC

获取价格

Industrial Control IC
1840-05AK20M ETC

获取价格

Industrial Control IC
1840-05AK20R ETC

获取价格

Industrial Control IC
1840-05AK21M ETC

获取价格

Industrial Control IC
1840-05AK21R ETC

获取价格

Industrial Control IC
1840-05AK30M ETC

获取价格

Industrial Control IC