General Purpose Relays
PCB Relays
OEG
Miniature PCB Relay PCH
n
n
n
5 to 10A rating
1 form A (NO) and 1 form C (CO) contact arrangements
Sensitive coil available for 1 form A type
Typical applications
Appliances, HVAC, refrigerators, microwave ovens
F_PCH_B
V Z
Approvals
VDE 119568, UL E82292, CQC08001023449
Technical data of approved types on request
Coil Data (continued)
Coil versions, DC coil
Coil
code
Rated
voltage
VDC
Operate
voltage
VDC
Release
voltage
VDC
Coil
resistance
Ω 10 %
Rated coil
power
mW
Contact Data
Contact arrangement
Rated voltage
1 Form A (NO)
30VDC, 277VAC
30VDC, 277VAC
5 to 10A
Sensitive type (for form A type only)
Max. switching voltage
Rated current
Contact material
Min. recommended contact load
Frequency of operation
Operate/release time max.
Electrical endurance
003
005
006
009
012
018
024
048
3
5
6
2.25
3.75
4.50
6.75
9.00
13.50
18.00
36.00
0.15
0.25
0.30
0.45
0.60
0.90
1.20
2.40
45
125
180
405
720
1620
2880
11520
200
200
200
200
200
200
200
200
AgSnO2
100mA, 5VDC
360 ops./h
10/5ms
9
12
18
24
48
D type: 5A, 277VAC resistive, -30°C to +70°C100x103 ops.
L type: 5A, 277VAC resistive, -30°C to +70°C 30x103 ops.
D/L-WG type: 5A, 250VAC resistive, -40°C to +85°C 100x103 ops.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil versions, DC coil
Coil
Rated
voltage
VDC
Operate
voltage
VDC
Release
voltage
VDC
Coil
resistance
Ω 10 %
Rated coil
power
mW
Contact ratings
code
Type
Contact
Load
Cycles
IEC 61810
PCH-..2M-WG A (NO)
PCH-..D2-WG A of C
PCH-..D2M
PCH-..L2M
PCH-..D2
UL 508
PCH
Standard type
5A 250VAC res, 85°C
5A 250VAC res, 85°C
5A 250VAC res, 70°C
5A 250VAC res, 70°C
5A/3A 250VAC res, 40°C
100x103
100x103
100x103
30x103
003
005
006
009
012
018
024
048
3
5
6
2.10
3.50
4.20
6.30
8.40
12.60
16.80
33.60
0.15
0.25
0.30
0.45
0.60
0.90
1.20
2.40
23
63
90
202
360
810
1440
5760
400
400
400
400
400
400
400
400
A (NO)
A (NO)
C (CO)
9
30x103
12
18
24
48
A (NO)
A (NO)
10A 125VAC res, 85°C
5A 250VAC general use, 85°C
100x103
100x103
PCH
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Mechanical endurance, DC coil
10x106 operations
Coil Data
Coil voltage range
Operative range, IEC 61810
3 to 48VDC
2
Coil insulation system according UL
Class F
1
04-2012, Rev. 0412
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company