Max. Capacitance Unbalance Nom.Mutual Capacitance
66 pF/ft
15 pF/ft
Delay
Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
510 ns/100m 25 ns/100m
70 %
High Freq
Frequency
[MHz]
Max. Insertion Loss
(Attenuation)
Min.
Min.
Min.
Min.
Min. ACRF
Min. PSACRF
(PSELFEXT) [dB]
Min. RL (Return
Loss) [dB]
Max./Min. Input
Impedance (unFitted)
Max./Min. Fitted
Impedance
NEXT [dB] PSNEXT [dB] ACR [dB] PSACR [dB] (ELFEXT) [dB]
1 MHz
2 dB/100m
65.3 dB
56.3 dB
51.8 dB
50.3 dB
47.3 dB
45.8 dB
44.3 dB
42.9 dB
38.4 dB
35.3 dB
32.5 dB
30.8 dB
29.3 dB
28.2 dB
27.9 dB
27.2 dB
65.3 dB
56.3 dB
51.8 dB
50.3 dB
47.3 dB
45.8 dB
44.3 dB
42.9 dB
38.4 dB
35.3 dB
32.5 dB
30.8 dB
29.3 dB
28.2 dB
27.9 dB
27.2 dB
63.3 dB
52.3 dB
46.1 dB
43.9 dB
39.1 dB
35.2 dB
34.1 dB
31.3 dB
21.6 dB
17.1 dB
4.7 dB
3 dB
63.3 dB
52.3 dB
46.1 dB
43.9 dB
39.1 dB
35.2 dB
34.1 dB
31.3 dB
21.6 dB
17.1 dB
4.7 dB
3 dB
63.8 dB
51.7 dB
45.7 dB
43.8 dB
39.7 dB
37.7 dB
35.8 dB
33.9 dB
27.8 dB
23.8 dB
19.9 dB
17.7 dB
15.8 dB
14.2 dB
13.9 dB
12.9 dB
60.8 dB
20 dB
23 dB
24.5 dB
25 dB
25 dB
25 dB
24.3 dB
23.6 dB
21.5 dB
20.1 dB
19 dB
19 dB
18 dB
18 dB
18 dB
17 dB
100 ± 12 Ohm
100 ± 12 Ohm
100 ± 12 Ohm
100 ± 12 Ohm
100 ± 12 Ohm
100 ± 12 Ohm
100 ± 15 Ohm
100 ± 15 Ohm
100 ± 15 Ohm
100 ± 15 Ohm
100 ± 18 Ohm
100 ± 20 Ohm
100 ± 20 Ohm
100 ± 20 Ohm
100 ± 20 Ohm
100 ± 22 Ohm
105 ± 10 Ohm
100 ± 10
100 ± 10
100 ± 10
100 ± 10
100 ± 10
100 ± 10
100 ± 10
100 ± 10
4 MHz
4 dB/100m
48.7 dB
42.7 dB
40.8 dB
36.7 dB
34.7 dB
32.8 dB
30.9 dB
24.8 dB
20.8 dB
16.9 dB
14.7 dB
12.8 dB
11.2 dB
10.9 dB
9.9 dB
8 MHz
5.7 dB/100m
6.4 dB/100m
8.1 dB/100m
9.2 dB/100m
10.3 dB/100m
11.6 dB/100m
16.8 dB/100m
21.7 dB/100m
27.7 dB/100m
32 dB/100m
36.4 dB/100m
40.5 dB/100m
41.3 dB/100m
44.3 dB/100m
10 MHz
16 MHz
20 MHz
25 MHz
31.25 MHz
62.5 MHz
100 MHz
155 MHz
200 MHz
250 MHz
300 MHz
310 MHz
350 MHz
0 dB
0 dB
0 dB
0 dB
Voltage
UL Voltage Rating
300 V RMS
Temperature Range
Installation Temp Range:
UL Temp Rating:
-25°C To +75°C
60°C
Storage Temp Range:
Operating Temp Range:
-40°C To +85°C
-40°C To +75°C
Mechanical Characteristics
Bulk Cable Weight:
35 lbs/1000ft
Max Recommended Pulling
Tension:
40 lbs
Min Bend Radius/Minor Axis:
0.29 in
Standards
NEC/(UL) Specification:
CEC/C(UL) Specification:
ISO/IEC Compliance:
CPR Euroclass:
CMR, CMX-Outdoor
CMR
Other Standards
Eca
Data Category:
Category 5e
Telecommunications
Standards:
Category 5e - TIA 568C.2
NEMA WC-63.1 Category 5e, Ethernet/IP™ compliant, UL verified to Category 5e
Other Specification:
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/11/EC
Yes
(BFR):
EU Directive 2011/65/EU
Yes
(ROHS II):
EU Directive 2012/19/EU
Yes
(WEEE):
EU Directive 2015/863/EU:
EU Directive Compliance:
Yes
EU Directive 2003/11/EC (BFR)