MODEL: 10JFX
(Minimum span 3 mV, Input resistance 20 kΩ min.)
High-density Signal Conditioners 10-RACK
U2: Range ±1000 mV;
(Minimum span 30 mV, Input resistance 20 kΩ min.)
U3: Range ±10 V;
LINEARIZER
(field-programmable)
(Minimum span 0.3 V,Input resistance 1 MΩ min.)
Functions & Features
• Accepting non-linear input and providing two linearized
outputs, proportional to the process variables
• Micro-processor based
[2] OUTPUT 1
Current
A: 4 – 20 mA DC (Load resistance 600 Ω max.)
Voltage
• On-site calibration up to 16 points using a hand-held
programmer PU-2x
6: 1 – 5 V DC (Load resistance 500 Ω min.)
• Field-programmable input range
• Optional second channel output available at the front
terminals and at the Standard Rack connector
[3] OUTPUT 2
0: None
Typical Applications
Voltage
• V-notch weir
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
• Gas analyzer
• Irregular-shaped tank level input for volume calculation
POWER INPUT
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[4] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
MODEL: 10JFX–[1][2][3]–R[4]
/C03: Rubber coating
ORDERING INFORMATION
• Code number: 10JFX-[1][2][3]-R[4]
Specify a code from below for each [1] through [4].
(e.g. 10JFX-6A6-R/Q)
RELATED PRODUCTS
• Programming Unit (model: PU-2x)
• PC configurator software (model: JXCON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
• Special input range (For codes U1, U2 & U3)
• Linearization data (max. 16 points)
Use Ordering Information Sheet (No. ESU-1669) to specify
linearization data when the I/O signals are nonlinear.
• Specify the specification for option code /Q
(e.g. /C01)
GENERAL SPECIFICATIONS
Construction: Rack-mounted; terminal access via screw
terminals at the front and via card-edge connector at the
rear; terminal cover provided
[1] INPUT
Current
A: 4 – 20 mA DC (Input resistance 250 Ω)
H: 10 – 50 mA DC (Input resistance 100 Ω)
Voltage
Connection
Input: M3.5 screw terminals (torque 0.8 N·m)
Output: Card-edge connector and M3.5 screw terminals
(torque 0.8 N·m)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
U1: Range ±100 mV;
http://www.m-system.co.jp/
10JFX SPECIFICATIONS