M20S-02250A122, M20E-02250A222 | M2000 RES/EDM
MULTIPLE LIGHT BEAM SAFETY DEVICES
Hard wired
Configuration method
Display elements
LEDs
7-segment display
Fieldbus, industrial network
CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 2)
Integration via Flexi Soft safety controller
1)
Depending on load, power supply and wire cross-section. The technical specifications must be observed.
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
2)
Electrical data
III (EN 50178)
Protection class
Supply voltage VS
24 V DC (19.2 V DC ... 28.8 V DC) 1)
≤ 3.7 W (DC)
Power consumption
Safety outputs (OSSD)
Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored
1)
The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as
accessories from SICK.
Mechanical data
48 mm x 40 mm
Housing cross-section
Ambient data
IP65 (EN 60529)
Enclosure rating
0 °C ... +55 °C
Ambient operating temperature
Storage temperature
Air humidity
–25 °C ... +70 °C
15 % ... 95 %, Non-condensing
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
10 g, 16 ms (IEC 60068-2-29)
Vibration resistance
Shock resistance
Other information
950 nm
Wave length
2017-06-14 08:06:28 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK