M
ODELS LT/MLT
•
LINEAR POSITION TRANSDUCER
TECHNICAL SPECIFICATIONS
DIMENSIONS
OPTIONS**
MODELS
LT
MLT
• Other resistance values
• Independent Linearity to ± .1%
Travels > 1 inch*
• Water resistant seal***
• Three pin connector for MLT
MECHANICAL
Total Mechanical Travel
1.05 to 10.05 in. (min)
26.7 to 255.3 mm (min)
.55 to 6.05 in. (min)
13.9 to 153.7 mm (min)
1.0 oz (max)
Starting Force
Shock
DIMENSIONS
50 g 11 ms half sine
20 g rms 5 Hz to 2 KHz (MLT only)
One billion dither operations
1.00 (Retracted)
(25.4)
Housing length
(Electrical travel + 1.50 in.)
.50 Dia.
(12.7)
Vibration
Life
.125 Dia.
(3.1)
ELECTRICAL
1 to 10 in.
(25.4 to 254.0mm)
1/2 to 6 in.
(12.7 to 152.4mm)
#4-40 UNC-2A
Thd x .50 in. long
Theoretical Electrical
Travel (in 1" increments)
#28 jacketed cable 6" long, min.
(Color coded per schematic)
xx.xx = inches
(xx.xx) = mm
±1.0%
±20%
Independent Linearity
Total Resistance
1000 Ω/in.
electrical trave
1500 Ω/in.
electrical travel
(Black)
Ground
(Red)
V-in
Shaft Extended
Resistance Tolerance
Operating Temperature
Resolution
(Brown)
V-out
-40° to 80°C (-40° to 176°F)
Connect to high impedance circuit
Infinite
SCHEMATIC DIAGRAM
1000 MΩ @ 500 Vdc
500 MΩ @ 500 Vdc
Insulation Resistance
Dielectric Strength
Power Rating
1000 V rms
Housing length
[Electrical travel +1.2" (30.48)]
#4-40 UNF-2B
.063
(1.6)
0.25 Watt/in.
0.20 Watt/in.
.125 Dia.
(3.1)
electrical travel
electrical travel
<1µA
Recommended Wiper Current
.375 Dia.
(9.53)
.187 Dia.
(4.76)
.50
(12.7)
3 - Conductor cable
#26 AWG (65/44) 12" (305) long min.
(Color coded per schematic)
.75 Retracted
(19.05)
xx.xx = inches
(xx.xx) = mm
(Black)
Ground
(Red)
V-in
Shaft Extended
(Orange)
V-out
Connect to high impedance circuit
SCHEMATIC DIAGRAM
.625
(15.87)
.17
Extended Retracted
(4.3)
(Red)
(Black)
.125
(3.17)
.37
(9.4)
.25
(6.35)
M6 x 3 Thread
#4-40 UNF-2B
Wiper
Optional MLT connector
Metric Shaft Adapter
.32
(8.0)
.75
(19.0)
*5-95% of Theoretical Electrical Travel
**Minimum quantities may be required.
***LT only, 12 oz. (340 g) max. starting force
MLT Mating Connector
NOTE: Do not test using an Ohmeter on Rx 1 scale or other current devices.
Excessive wiper current can cause output error or damage.
Zero side load is recommended to achieve maximum life.
■
23
1
- 8 0 0 - 3 3 3 - D A T A