Features
ꢀ
ꢀ
ꢀ
ꢀ
Ensures standard press shut height to allow interchanging of applicators
May be used in most industry-standard crimp presses designed to 135.8mm shut height
Applies 850kgf (1870 lbf) load to press during measurement
Measurement range: 135.8mm ±0.2mm (5.346 in. ± 0.008 in.)
CAP
Scope
The Press Shut Height Gauge will measure the shut height of the
following Molex presses:
TM-2000 (63800-8300 and 63800-8400)
TM-3000 (63801-7200 and 63801-7300)
TM-4000 (63801-7600)
Other industry-standard presses (with quick-change mini-applicator
mounting and 135.8mm shut height) can also be measured with this
gauge. Spacers are NOT furnished for other shut heights.
DIAL
BOTTOM
PLATE
Description
Figure 1
The principal parts of the Press Shut Height Gauge are shown in Figure 1.
Operation
To measure the press shut height, use the following procedure:
1. Disconnect electrical power from the press.
2. Remove the crimp applicator from the press.
3. Wipe the applicator mounting surfaces (upper and lower) in the press clean.
4. Hand-cycle the press ram to its highest position (TDC).
5. Place the Shut Height Gauge in the press with the cap centered under the ram and the bottom plate resting flat on
the press base plate. See Figure 2.
Note: Some presses may require some mounting hardware to be loosened or removed from the base plate so the
Shut Height Gauge can rest flat.
Doc No: ATS-638007900 Release Date: 09-03-09
Revision: D Revision Date: 04-20-11
UNCONTROLLED COPY