05S2
THRU
05S6
SURFACE MOUNT FAST RECOVERY RECTIFIER
VOLTAGE RANGE 20 to 60 Volts CURRENT 0.5 Ampere
FEATURES
* Low power loss, high efficiency
* Low leakage
* Low forward voltage
* High current capability
* High speed switching
* High surge capabitity
* High reliability
SOD-123F
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
* Mounting position: Any
.114 (2.9)
.106 (2.7)
.077 (1.95)
.069 (1.75)
.035 (0.90)
* Weight: 0.016 gram
.028 (0.70)
.008 (0.20)
.053 (1.35)
.047 (1.20)
.030 (0.75)
.022 (0.55)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.150 (3.8)
.142 (3.6)
Dimensions in inches and (millimeters)
O
MAXIMUM RATINGS (@ T
A
=25 C unless otherwise noted)
SYMBOL
05S2
20
05S3
30
05S4
40
05S5
50
UNITS
Volts
Volts
Volts
RATINGS
05S6
60
V
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
RRM
V
14
21
28
35
42
RMS
V
DC
20
30
40
50
60
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
I
0.5
Amps
Amps
0 C/W
O
.375” (9.5mm) lead length at T =550C
A
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
I
FSM
15
R
130
θJA
Typical Thermal Resistance (Note 3)
R
30
110
150
θJL
C
J
Typical Junction Capacitance (Note 1)
Operating Temperature Range
Storage Temperature Range
pF
0 C
0 C
T
J
T
-55 to + 150
STG
O
ELECTRICAL CHARACTERISTICS(@T
A
=25 C unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 0.5A DC
Maximum Average Reverse Current
SYMBOL
05S2
05S3
.55
05S4
05S5
05S6
UNITS
Volts
.70
V
F
@T = 25oC
0.2
10
mAmps
mAmps
A
I
R
at Rated DC Blocking Voltage
@T = 100oC
A
NOTES : 1. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
2. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
3. Thermal Resistance : Mounted on PCB.
2006-11