Surface Mount Fuses
Ceramic Fuse > 501A Series
RoHS Pb
501A Series – High Current 1206 Fast-Acting Fuse
Description
The 501A series AECQ-Compliant fuses and Halogen free
fuse series are specifically tested to cater to secondary
circuit protection needs of compact auto electronics
application.
The general design ensures excellent temperature stability
and performance reliability. The high I2t values which are
typical in the Littelfuse Ceramic Fuse family, ensure high
inrush current withstanding capability.
Features
• OperatingTemperature
from -55ºC to +125ºC
• Suitable for both leaded
and lead-free reflow/wave
soldering
Agency Approvals
AGENCY
AGENCY FILE NUMBER
AMPERE RANGE
10A - 20A
• Meets Littelfuse’s
automotive qualifications*
E10480
29862
• 100% Lead-free, RoHS
compliant and
10A - 20A
Halogen-free
* Largely based on Littelfuse internal AEC-Q200 test plan
Electrical Characteristics for Series
% of Ampere
Ampere Rating
OpeningTime at 25ºC
Applications
Rating
100%
350%
10A – 20A
10A – 20A
4 Hours, Minimum
• Li-ion Battery
• TFT Display
5 Seconds, Maximum
• LED Head-Lights
• Battery Management
System (BMS)
• Automotive Navigation
System
• Clusters
Additional Information
ꢀatasꢁeet
ꢀesources
Saꢀꢁꢂes
Electrical Specifications by Item
Agency Approvals
Ampere
Rating
(A)
Max.Voltage
Rating
Interrupting
Nominal
Nominal
Nominal Voltage
Drop at Rated
Current (V) 4
Nominal Power
Amp
Code
Rating
Resistance Melting I2t
Dissipation at
(V)
(DC) 1
(Ohms) 2
(A2Sec.) 3
Rated Current (W)
10
12
15
20
010.
012.
015.
020.
32
32
32
32
0.00362
0.00311
0.00250
0.00194
10.385
20.341
39.700
86.360
0.04407
0.04927
0.04843
0.05888
0.4407
0.5912
0.7265
1.1776
x
x
x
x
x
x
x
x
150A @ 32VDC
Notes:
Devices designed to carry rated current for four hours minimum. It is recommended that
devices be operated continuously at no more than 80% rated current. See “Temperature
Re-rating Curve” for additional re-rating information.
1. DC Interrupting Rating tested at rated voltage with time constant <0.5msec.
2. Nominal Resistance measured with <10% rated current.
3. Nominal Melting I2t measured at 1 msec. opening time. For other I2t data refer to chart.
Devices designed to be mounted with marking code facing up.
4. Nominal Voltage Drop measured at rated current after temperature has stabilized and
with fuse mounted on board with 3oz Cu trace.
© 2018 Littelfuse, Inc.
Specifications are subject to change without notice
Specifications are subject to change without notice. Application testing is strongly recommended.