Special Load PCB Relay 409 47, 409 67
1 pole 10 A, for high inrush currents,
mono- or bistable
Features
•
•
•
•
•
Specifically designed to handle high inrush currents
Tungsten prerun contact
500 A / 10 ms inrush peak current
4 kV / 8 mm coil-contact
meets protection class II requirements
Applications
Dimmer switches, movement sensors, filament loads, halogen
bulbs, motors and electrovalves
Z
(409 47 only)
Technical data of approved types on request
F0249-A
Contact data
Configuration
1 N/O contact
Type of contact
Rated current
single contact
10 A
Rated voltage / max.breaking voltage AC
Maximum breaking capacity AC
Make current (max. 4 s at duty cycle 10%)
peak inrush current 10 µs / 20 ms
Contact material
250 Vac / 400 Vac
2500 VA
16 A
500 / 120 A
W (prerun contact) + AgCdO
Contact ratings
Type
409
409
409
409
Load
Operations
2.5x105
3x104
Standard
10 A, 250 Vac, resistive
1300 W, fluorescent lamps, 140 µF
2500 W, incandescent lamps
1000 W, Dulux lamps, 140 µF
3x104
3x104
Coil data
monostable DC coil
5...110 Vdc
820 mW
Nominal voltage
Nominal coil power
Operate category
2 / b
Coil versions monostable
Coil
code
Nominal
voltage
Vdc
Pull-in
voltage
Vdc
Release
voltage
Vdc
Maximum
voltage
Vdc
Coil
resistance
c
Coil
current
mA
031
027
024
023
12
24
48
60
7.5
18.0
34.5
41.0
0.9
1.8
3.6
4.5
14.2
34.6
60.6
77.8
170+10%
880+15%
2700+15%
4400+15%
71.0
27.0
18.0
14.0
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request