Integrated Color Space / Raster-To-Block Converter
Window Area Register PAY-Hi
Number Of Lines Register NOL-Hi
Read/Write
Initial Value
Indirect address: 0x09
0x00
Read Only
Initial Value
Indirect address: 0x0B
PAY[15:8]
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
PAY[15:8]
PAY[15:8]
Bits 0-7 PAY(15:8): The number of lines of the active
Bits 0-7 NOL(15:8): The number of processed lines when
window area {Y-axis dimension]. Upper 8 bits.
compressing. Upper 8 bits.
Initial Value = 0x00.
Initial Value = PAY(15:8).
The logical value of PAY is the same as its literal
value for all literal values up to and including
0xFFFE. Thus, the logical value for literal PAY =
0xFFFE (65534) is 65534 pixels. The logical value
for literal PAY = 0xFFFF (65535) is 65536 pixels. If
PAY = 0 in compression, then the number of lines
processed is determined by the active period of
VIN. PAY (logical) must be an even number when
vertical decimation/interpolation is used.
If PAY≠0, its logical value determines the number of
lines actually processed in compression. If PAY = 0,
the ZR36016 processes all lines input until the
falling edge of VIN. If the number of lines input
during the active period of VIN is not an exact
multiple of the strip height (see Table 19), then the
ZR36016 will abandon the incomplete strip. The
NOL register will indicate only the number of lines
actually processed.
In the sequential mode, the value read from this
register is the number of lines processed in the
previous VIN active interval.
HIN
Enabled Area
If 65536 lines are processed, the value in NOL will
be 0x0000. The ZR36016 can process a maximum
of 65536 lines. If the number of lines exceeds
65536, then the ZR36016 terminates the process-
ing after 65536 lines.
Active Window Area
NAX
PAX
Figure 4. Active Window Area
Number Of Lines Register NOL-Lo
Read Only
Initial Value
Indirect address: 0x0A
PAY[7:0]
7
6
5
4
3
2
1
0
NOL[7:0]
Bits 0-7 NOL(7:0): The actual number of lines that were pro-
cessed in compression. Lower 8 bits.
Initial Value = PAY(7:0).
8