5秒后页面跳转
ZM7332G-65508X-T1 PDF预览

ZM7332G-65508X-T1

更新时间: 2023-01-02 18:39:44
品牌 Logo 应用领域
BEL /
页数 文件大小 规格书
32页 1412K
描述
Power Management Circuit, PQCC64

ZM7332G-65508X-T1 数据手册

 浏览型号ZM7332G-65508X-T1的Datasheet PDF文件第4页浏览型号ZM7332G-65508X-T1的Datasheet PDF文件第5页浏览型号ZM7332G-65508X-T1的Datasheet PDF文件第6页浏览型号ZM7332G-65508X-T1的Datasheet PDF文件第8页浏览型号ZM7332G-65508X-T1的Datasheet PDF文件第9页浏览型号ZM7332G-65508X-T1的Datasheet PDF文件第10页 
ZM7300G Series Digital Power Manager  
Data Sheet  
9
Typical Application  
Figure 3. Typical Application Schematic of Multiple Output System with Digital Power Manager and I2C Interface  
The schematic of a typical application of a ZM7300 digital power manager (DPM) is shown in Figure 3. The  
system includes four groups of Z-One Point Of Load converters (POLs). A group is defined as one or more POL  
converters interconnected via OK pins. Grouping of the POLs enables users to program advanced fault  
management schemes and define margining functions, monitoring, startup behavior, and reporting conventions.  
All Z-One POL converters are connected to the DPM and to each other via a single-wire synchronization/data (SD)  
line. The line provides synchronization of all POL converters to the master clock generated by the DPM and  
simultaneously carries bidirectional data transfer between POL converters and the DPM. The DPM communicates  
via the I2C bus with the host system and/or the Graphical User Interface.  
In this application, besides Z-One POL converters, the DPM also controls and monitors two auxiliary devices – a  
Voltage Regulation Module (VRM) and a Low Dropout Regulator (LDO). While these devices are not Z-One  
compliant and may not even be manufactured by Power-One, they are integrated into the system by  
communicating with the DPM via their Enable pins connected to ENX outputs of the DPM. In addition, the DPM  
monitors status of the auxiliary devices via its PGX inputs connected to Power Good and Error Flag outputs of the  
auxiliary devices. The DPM can control and monitor four or more independent auxiliary devices.  
The DPM can also trigger an optional crowbar circuit and provide undervoltage and overvoltage protections of the  
intermediate bus voltage. In addition, the DPM can be controlled by a host system via the interrupt inputs, RES_N  
input, and the ACFAIL inputs.  
REV. 3.0 MAR 01, 2007  
www.power-one.com  
Page 7 of 32  
 

与ZM7332G-65508X-T1相关器件

型号 品牌 获取价格 描述 数据表
ZM7332G-65508Y-B1 POWER-ONE

获取价格

Digital Power Manager
ZM7332G-65508Y-B2 POWER-ONE

获取价格

Digital Power Manager
ZM7332G-65508Y-Q1 POWER-ONE

获取价格

Digital Power Manager
ZM7332G-65508Y-T1 POWER-ONE

获取价格

Digital Power Manager
ZM7332G-65508Y-T2 POWER-ONE

获取价格

Digital Power Manager
ZM734G-65505A-B2 BEL

获取价格

Power Supply Management Circuit, Fixed, 1 Channel, 9 X 9 MM, ROHS COMPLIANT, MO-220, QFN-6
ZM734G-65505A-T2 BEL

获取价格

Power Supply Management Circuit, Fixed, 1 Channel, 9 X 9 MM, ROHS COMPLIANT, MO-220, QFN-6
ZM738G-65506A-B1 BEL

获取价格

Power Supply Management Circuit, Fixed, 1 Channel, 9 X 9 MM, ROHS COMPLIANT, MO-220, QFN-6
ZM738G-65506A-B2 BEL

获取价格

Power Supply Management Circuit, Fixed, 1 Channel, 9 X 9 MM, ROHS COMPLIANT, MO-220, QFN-6
ZM738G-65506A-Q1 BEL

获取价格

Power Supply Management Circuit, Fixed, 1 Channel, 9 X 9 MM, ROHS COMPLIANT, MO-220, QFN-6