Z-15 (Flexible Rod Models)
Rated voltage
Non-inductive load (A)
Resistive load Lamp load
NC NO
Inductive load (A)
Inductive load Motor load
NC NO
NC
NO
NC
NO
125 VAC
250 VAC
15
15
2
1
1
0.5
7
5
2.5
1.5
2
1
8 VDC
15
15
2
0.4
0.2
2
2
2
0.4
0.2
1
1
1
0.4
0.2
7
7
1
0.03
0.02
3
3
1
0.03
0.02
1.5
1.5
0.5
0.03
0.02
14 VDC
30 VDC
125 VDC
250 VDC
Z-10F
Item
Non-inductive load (A)
Inductive load (A)
Resistive load
Lamp load
Inductive load
Motor load
Rated
voltage
Contact gap
NC
NO
NC
NO
NC NO
NC
NO
125 VAC
250 VAC
10
10
4
2.5
2
1.5
6
6
5
3
2.5
1.5
Series
connection
30 VDC
125 VDC
250 VDC
10
1
0.6
4
1
0.6
2
1
0.6
6
0.1
0.05
6
0.1
0.05
3
0.1
0.05
125 VAC
250 VAC
6
6
3
2.5
1.5
1.25
4
4
4
2
2
1
Parallel
connection
30 VDC
125 VDC
250 VDC
6
0.6
0.3
4
0.6
0.3
2
0.6
0.3
4
0.1
0.05
6
0.1
0.05
3
0.1
0.05
Z-01H
■ Contacts Specification
Resistive load (A)
Rated voltage
Item
Classification
Shape
Z-15
Rivet
Silver
Z-01H
Z-10F
Rivet
Silver
NC
NO
Single
crossbar
125 VAC
0.1
Contacts
8 VDC
14 VDC
30 VDC
0.1
0.1
0.1
Material
NC
Gold alloy
30 A max. 0.1 A max. 40 A max.
15 A max. 0.1 A max. 20 A max.
Inrush current
NO
Applicable Load Range
5 mW
800 mW
■ Safety Standards Ratings
0.16 mA
30
26 mA
UL/CSA (General ratings only)
Standard load
area
Z-15H, H2
Z-15G
Z-15E
Z-10FY
Z-15ER
24
12
Rated
Model
Z-15
Z-10F
Z-01H
voltage
Micro load area
Z-01H
125 VAC
250 VAC
480 VAC
30 VDC
15A and 1/8HP 6A and 1/10HP
15A and 1/4HP 6A and 1/8HP
0.1A
---
15A
---
6A
---
---
Unusable
range
0.1A
---
125 VDC
250 VDC
0.5A
0.25A
0.6A
0.3A
5
1 mA
100 mA 160 mA
---
0
0.1
1
10
100
1,000
TÜV (EN61058-1)
Current (mA)
Rated
Model
voltage
Z-15H@-B
Z-15G@-B
Z-01H@-B
Z-01H
Z-15
@
, Z-10FY
Minimum applicable load
1 mA at 5 VDC 160 mA at 5 VDC
250 VAC
125 VAC
30 VDC
15 A
---
15 A
---
---
0.1 A
0.1 A
---
---
Note: 1. The above current ratings are the values of the steady-state current.
2. Inductive load has a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
6. The AC ratings of molded terminals are 125 and 250 V only.
7. The ratings values apply under the following test conditions:
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%RH
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
(3) Operating frequency: 20 operations/min
5. The normally closed and normally open ratings of reverse hinge
lever models are opposite to each other.
General-purpose Basic Switch Z
153