5秒后页面跳转
Z01H55 PDF预览

Z01H55

更新时间: 2022-09-10 15:43:22
品牌 Logo 应用领域
欧姆龙 - OMRON 开关
页数 文件大小 规格书
28页 5911K
描述
General-purpose Basic Switch

Z01H55 数据手册

 浏览型号Z01H55的Datasheet PDF文件第3页浏览型号Z01H55的Datasheet PDF文件第4页浏览型号Z01H55的Datasheet PDF文件第5页浏览型号Z01H55的Datasheet PDF文件第7页浏览型号Z01H55的Datasheet PDF文件第8页浏览型号Z01H55的Datasheet PDF文件第9页 
Specifications  
Characteristics  
Z-15  
Z-15  
(flexible rod)  
Classification  
(except micro load  
and flexible rod)  
Z-01H  
Z-10F  
Z-15H2  
Item  
Operating speed  
0.01 mm to 1 m/s (*1)  
240 operations/min  
20 operations/min  
1 mm to 1 m/s  
120 operations/min  
0.1 mm to 1 m/s (*1)  
240 operations/min  
0.01 mm to 1 m/s  
240 operations/min  
Mechanical  
Electrical  
Operating  
frequency  
15 m  
Ω
max. (initial value) 50 m  
Ω
max. (initial value) 15 mΩ max. (initial value)  
25 mΩ max. (initial value) 15 mΩ max. (initial value)  
Contact resistance  
100 MΩ min. (at 500 VDC)  
Insulation resistance  
Between contacts of same polarity  
Contact gap G: 1,000 VAC  
Contact gap H: 600 VAC  
Between contacts of same polarity Between contacts of  
Between contacts of  
same polarity  
Contact gap G: 1,000 VAC  
Contact gap H: 600 VAC  
same polarity  
Contact gap F: 1,500 VAC 600VAC  
Dielectric strength  
(50 / 60 Hz for 1 min.)  
Contact gap E: 1,500 VAC  
Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts:  
2,000 VAC  
10 to 55 Hz, 1.5-mm double amplitude (*5)  
10 to 20 Hz, 1.5-mm double amplitude (*5) 10 to 55 Hz, 1.5-mm double amplitude (*5)  
Vibration  
resistance  
Malfunction  
Destruction 1,000 m/s2 max.  
Malfunction 300 m/s2 max. (*2, *5)  
Shock  
resistance  
50 m/s2 max. (*5)  
300 m/s2 max. (*3, *5) 100 m/s2 max.  
IP00  
General-  
purpose  
Degree of  
protection  
Equivalent to IP62 (except terminals)  
Class I  
Drip-proof  
Degree of protection  
against electric shock  
175  
Proof tracking index  
(PTI)  
25°C to 80°C (with no icing)  
General-  
Ambient  
purpose  
operating  
temperature  
15°C to 80°C (with no icing)  
Drip-proof  
35% to 85%RH  
General-  
purpose  
Ambient  
operating  
humidity  
35% to 95%RH  
Drip-proof  
Contact gap H2: 10,000,000 operations min.  
Contact gap G, H: 20,000,000 operations min.(*4)  
Contact gap E: 300,000 operations  
1,000,000 operations min.  
500,000 operations min. (*1) 20,000,000 operations min.  
100,000 operations min. 500,000 operations min.  
Mechanical  
Service life  
Weight  
Contact gap G, H: 500,000 operations min.  
Contact gap E: 100,000 operations min.  
100,000 operations min.  
Approx. 42 to 48 g  
Electrical  
Approx. 22 to 58 g  
Approx. 34 to 61 g  
Approx. 22 g  
*1 The values are for the plunger models. (For the lever models, the values are  
at the plunger section.)  
*2 The values are for the Z-15G pin plunger.  
*3 The values are for the Z-10FY-B.  
*4 The values are for the pin plunger. The service life for models other than the  
pin plunger is 10,000,000 min.  
*5 Malfunction: 1 ms max.  
Ratings (Basic, Split-contact and Maintained contact Models)  
Z-15 (Except Micro Load and Flexible Rod Models)  
Non-inductive load (A)  
Resistive load Lamp load  
NC NO  
Inductive load (A)  
Inductive load  
NC NO  
Item  
Motor load  
Contact gap  
Rated voltage  
125 VAC  
NC  
3
NO  
1.5  
1.25  
0.75  
1.5  
1.5  
1.5  
0.5  
0.25  
1.5  
1.5  
1.4  
0.4  
0.2  
1.5  
1.5  
1.5  
0.75  
0.3  
NC  
5
NO  
2.5  
1.5  
0.75  
2.5  
2.5  
2.5  
0.05  
0.03  
2.5  
2.5  
1
0.03  
0.02  
2.5  
2.5  
2.5  
0.4  
0.2  
15 (10) *  
15 (10) *  
10  
15 (10) *  
15 (10) *  
6
G, H, H2, E 250 VAC  
500 VAC *  
2.5  
1.5  
3
3
1.5  
8 VDC  
14 VDC  
15  
15  
5
15  
3
10  
5
G
H, H2  
E
30 VDC  
125 VDC  
250 VDC  
8 VDC  
14 VDC  
30 VDC  
125 VDC  
250 VDC  
8 VDC  
14 VDC  
30 VDC  
125 VDC  
250 VDC  
6
3
5
5
0.5  
0.25  
15  
0.5  
0.25  
3
0.05  
0.03  
15  
0.05  
0.03  
5
15  
3
10  
5
2
2
1
1
0.4  
0.2  
15  
0.4  
0.2  
3
0.03  
0.02  
15  
0.03  
0.02  
5
15  
3
15  
5
15  
3
10  
5
0.75  
0.3  
0.75  
0.3  
0.4  
0.2  
0.4  
0.2  
* Figures in parentheses are for the Z-15HW52, Z-15HW78(-B) and Z-15H2(-B) models, the AC ratings of these models are 125 and 250 V only.  
152  
General-purpose Basic Switch Z  

与Z01H55相关器件

型号 品牌 描述 获取价格 数据表
Z-01H55 OMRON General-purpose Basic Switch

获取价格

Z-01H55-B OMRON General-purpose Basic Switch

获取价格

Z01HB OMRON General-purpose Basic Switch

获取价格

Z-01H-B OMRON General-purpose Basic Switch

获取价格

Z-01HD OMRON General-purpose Basic Switch

获取价格

Z-01HD55 OMRON General-purpose Basic Switch

获取价格