XUQ DATASHEET
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the XUQ. These ratings, which are standard values for
IDT commercially rated parts, are stress ratings only. Functional operation of the device at these or any other conditions above
those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions
for extended periods can affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Rating
VDD
E/D
-0.5 to +5.0V
-0.5V to VDD + 0.5V
-0.5V to VDD + 0.5V
-55°C to 125°C
OUT
Storage Temperature
Theta Ja (Junction to Ambient)
102°C/W – Still Air
ESD Compliance
Human Body Model (HBM)
Machine Model (MM)
1000V
150V
Mechanical Testing
Parameter
Test Method
Mechanical Shock
Half-Sine wave with 0.3ms 3000G
X, Y, Z each direction 1 time
Mechanical Vibration
Frequency: 10 to 55 MHz Amplitude: 1.5mm
Frequency: 55~2000Hz Peak value: 20G
Duration time: 4H for each X,Y,Z axis Total 12hours
High Temp Operating Life (HTOL)
Hermetic Seal
2000 Hours 125°C (under power)
Gross leak (Air leak test)
Fine leak (Helium leak test) He-pressure: 6kgf/cm² 2 hours
Solder Reflow Profile
tP
10 seconds Max within
5°C of 260°C peak
260°C
Ramp up 3°C/s Max
Ramp down not
to exceed 6°C/s
225°C
180°C
50 ±10
seconds
above 225°C
reflow area
120 ±20 seconds
in pre-heating
area
160°C
25°C
400 seconds MAX from +25°C to 260°C peak
IDT XO LVPECL CRYSTAL OSCILLATOR
2