XLP DATASHEET
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the XLP. These ratings, which are standard values for
IDT commercially rated parts, are stress ratings only. Functional operation of the device at these or any other conditions above
those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions
for extended periods can affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Rating
VDD
E/D
-0.5 to +5.0 V
-0.5 V to VDD + 0.5 V
-0.5 V to VDD + 0.5 V
-55°C to 125°C
OUT
Storage Temperature
Theta Ja (Junction to Ambient)
102°C/W – Still Air
ESD Compliance
Human Body Model (HBM
Machine Model (MM)
1000V
150V
Mechanical Testing
Parameter
Mechanical Shock
Test Method
Drop from 75cm to hardwood surface–3 times
Mechanical Vibration
10~55Hz, 1.5mm amplitude, 1 minute sweep
2 hours each in 3 directions (X, Y, Z)
High Temperature Burn-in
Hermetic Seal
Under power @ 125°C for 2000 hours
He pressure: 4 ±1kgf/cm2 2 hour soak
Solder Reflow Profile
tP
10 seconds Max within
5°C of 260°C peak
260°C
Ramp up 3°C/s Max
Ramp down not
to exceed 6°C/s
225°C
180°C
50 ±10
seconds
above 225°C
reflow area
120 ±20 seconds
160°C
in pre-heating
area
25°C
400 seconds MAX from +25°C to 260°C peak
IDT XO LVPECL CRYSTAL OSCILLATOR
2
REVISION B 12/10/14