WRA-YMD-6W&WRB-YMD-6W Series
TYPICAL CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
Temperature Derating Graph
Parameter
Conditions
Min.
Typ.
500
Max.
95
Units
Storage humidity range
NO-load power consumption
Operating temperature
Storage temperature
Lead temperature
Temp.rise at full load
Cooling
%
MW
°C
-40
-55
85
125
300
°C
1.5mm from case for 10 seconds
°C
15
°C
Free air convection
Plastic(UL94-V0)
Case material
Short circuit protection*
Case material
Continuous,automatic recovery
Copper metal or Aluminum alloy
K hours
MTBF
1000
Weight
15
g
*Supply voltage must be discontinued at the end of short circuit duration.
RECOMMENDED CIRCUIT
ISOLATION SPECIFICATIONS
OUTPUT Graph
Parameter
Test conditions
Min.
Typ.
100
Max.
Units
Flash tested for 1 minute and 1mA max
Test at Viso=500VDC
Isolation test voltage
Isolation resistance
Isolation capacitance
1500
1000
VDC
MΩ
pF
Input/Output
APPLICATION NOTE
1) Requirement on output load
In order to ensure the product operate efficiently and reliably, in addition to a max load (namely full
load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of
input voltage is not exceeded, the minimum output load no less than 10% load. If the actual load is less
than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability
will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra
loading, or contact our company for other lower output power products.
2) Recommended Circuit
All the WRA_YMD-6W
& WRB_YMD-6W Series have been tested according to the following
recommended testing circuit before leaving factory. This series should be tested under load. Never be
tested under no load (see Figure 1).
If you want to further decrease the input/output ripple,you can increase capacitance properly or
choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be proper.
If the capacitance is too big, a startup problem might arise. For every channel of output,provided the safe
and reliable operation is ensured,the greatest capacitance of its filter capacitor sees (Table 1). General:
Cin:
5V&12V
100μF
24V&48V
10μF-47μF
Cout: 10PF/100mA
3) Input current
When it is used in unregulated power supply,be sure that the fluctuating range of the power supply
and the rippled voltage do not exceed the module standard.Input current of power supply should afford
the startup current of this kind of DC/DC module (Figure 2).
EXTERNAL CAPACITOR TABLE (TABLE 1)
General: Ip≤1.4*Iin-max
Single Vout
Cout
(μF)
2200
1000
680
Dual Vout
Cout
(μF)
680
470
330
220
_
(VDC)
3.3
5
(VDC)
±5
4) No parallel connection or plug and play
±9
9
±12
±15
_
12
470
15
330
24
220
_
_
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 3