Customer Approval Sheet
Test item
Test condition
Criteria
1. VcPer IEC 61000-4-2,@500V, clamp
measurement made 30 ns after
initiation of pulse, all test in contact
discharge mode.
1. Inductance value should be
within ± 20 % of the initial value.
2. Appearance without damage.
ESD Test
2. ESD pulse : 10 hits.
Resistance to
Solvent
Refer to MIL-STD-202-215 test Solvent
1~4.
Appearance without damage.
1. Testing sample should be welding on
board.
1. Inductance value should be
within ± 20 % of the initial value.
2. Appearance without damage.
Board Flex
2. Press the center of sample in the rate
1.0mm/sec until it is bend
to 3mm for 60sec.
1. Pulse shape:Half-sine waveform.
2. Impact acceleration:100g.
3. Pulse duration:6 ms.
1. Inductance value should be
within ± 20 % of the initial value.
2. Appearance without damage.
4. Number of shocks:18 shocks (3
shocks for each face).
Mechanical Shock
5. Orientation:Bottom, top, left, right,
front and rear faces.
1. Vibration waveform:Sine waveform.
2. Vibration frequency / Displacement:10
to 40 Hz/1.52 mm.
3. Vibration frequency/ Acceleration:40
to 2000 Hz/5 g.
1. Inductance value should be
within ± 20 % of the initial value.
2. Appearance without damage.
Vibration
4. Cycle time:20 minute.
5. Number of cycles:12 cycles for each
axis.
6. Vibration axes:X, Y and Z (Rotating
each axis on vertical vibration table).
Flammability, 50W (20mm) Vertical
Burning Test
Flammability Test
V-0 or V-1 Acceptable
Physical Dimension Microscope→10X
Appearance without damage
*The reliability test conditions are only briefly described, and the actual content is in accordance with
the AECQ-200.