WLC60 Heavy Duty Stainless Steel LED Light
For maximum intensity, leave the white and black wires floating or connected to common.
Specifications
Supply Voltage
Light Characteristics
Operating Voltage: 12 V dc to 30 V dc
Use only with a suitable Class 2 power supply (UL) or SELV power supply
(CE)
Color temperature (CCT): 6200K (+500, -550K)
Color: Cool white
Lumen Output
1300 lumens (typical at 25° C)
Luminous efficacy: 87 lumens/watts typical at 24 V dc at 25° C
CRI: 80, minimum
See electrical characteristics on product label
Max. Current
1.53 A at 12 V dc
0.68 A at 24 V dc
LED Lifetime
0.55 A at 30 V dc
Lumen Maintenance - L
70
Max. Input Power: 18.4 Watts
When operating within specifications, output will decrease less than 30%
Typical Current
after 60,000 hours
1.38 A at 12 V dc
0.62 A at 24 V dc
0.49 A at 30 V dc
Spacing Criterion
0.86
Test Data
LM-79, LM-80, TM-21
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Construction
Required Overcurrent Protection
316L stainless steel housing
Polycarbonate or borosilicate glass window
Buna o-ring seals (consult factory for additional seal)
WARNING: Electrical connections must be
made by qualified personnel in accordance with
local and national electrical codes and
regulations.
Connections
Integral 4-pin M12/Euro-style male quick disconnect
Mating cordset required for quick disconnect models
Overcurrent protection is required to be provided by end product
application per the supplied table.
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 1.0 mm peak-to-peak amplitude per IEC
60068-2-6
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
Operating Temperature
–40 °C to +50 °C (–40 °F to +122 °F) at the max. intensity setting
–40 °C to +70 °C (–40 °F to +158 °F) at any of the dim settings
Environmental Rating
IEC IP67, JIS C IP68G, IP69K per DIN 40050-9
Certifications
Performance
Polar Candela Distribution
Isolux Pattern
Illuminance at a Distance
0.5 m
0 m
0.5 m
Center Beam (lux)
5,759 lux
1,554 lux
714 lux
Beam Width (m)
0.5 m 0.5 m
1.0 m 1.0 m
1.5 m 1.5 m
1.9 m 2.0 m
180°
170°
160°
1500
1250
1000
750
150°
140°
130°
0.5 m
1.0 m
1.5 m
2.0 m
0.5 m
120°
110°
100°
500
407 lux
250
Vert.
Horiz.
0
90°
80°
Vertical Spread: 50.3°
0 m
250
Horizontal Spread: 45.5°
500
70°
60°
50°
40°
750
1000
1250
1500
30°
20°
0.5 m
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
1300 lux
1100 lux
900 lux
700 lux
500 lux
300 lux
200 lux
100 lux
50% max. lux
2
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 178410 Rev. H