VX  
Miniature Basic Switch  
Precautions  
Please refer to "Common Precautions" for correct use.  
Cautions  
Correct Use  
Handling  
Mounting  
Do not apply excessive shock. Doing so may cause damage to  
the Switch's internal components because it is designed for a  
small load.  
Use M3 mounting screw with plane washers or spring washers to  
securely mount the Switch. Tighten the screws to a torque of  
0.39 to 0.59 N·m {4 to 6 kgf·cm}.  
Soldering  
Mounting Direction  
V
X
• Terminal connections  
For a Switch with an actuator, mount the Switch in a direction  
where the actuator weight will not be applied to the Switch.  
Since the Switch is designed for a small load, its resetting force  
is small. Therefore, resetting failure may occur if unnecessary  
load is applied to the Switch.  
Complete the soldering at the iron tip temperature between  
250 to 350°C (60W) within 5 seconds, and do not apply any  
external force for 1 minute after soldering.  
Apply minimum amount of flux required. It may result in  
contact failure once the flux penetrates into the internal part of  
the Switch.  
Using Micro Loads  
Using a model for ordinary loads to open or close the contact of  
a micro load circuit may result in faulty contact. Use models that  
operate in the following range. However, even when using micro  
load models within the following operating range, if inrush  
current occurs when the contact is opened or closed, it may  
increase the contact wear and so decrease durability. Therefore,  
insert a contact protection circuit where necessary. The N-level  
reference value applies for the minimum applicable load. This  
value indicates the malfunction reference level for the reliability  
level of 60% (λ60).  
• Connecting to Tab Terminals (#187)  
When connecting to the Tab terminal, insert the receptacle of  
tab #187 straight toward the terminal.  
Applying excessive external force laterally may cause  
deformation of terminals and may damage the housings.  
(JIS C5003)  
The equation, λ60=0.5×10-6/operations operation, indicates that  
1
the estimated malfunction rate is less than  
with a reliability level of 60%.  
operations  
2,000,000  
0.16 mA  
26 mA 100 mA  
30  
24  
Operating  
range for  
general-load  
model  
Operating range for  
micro-load model  
VX-01  
VX-5  
12  
5
0
1 mA  
100 mA 160 mA  
0.1  
1
10  
100  
1,000  
Current (mA)  
6

与VX-014K-2C23相关器件

型号 品牌 描述 获取价格 数据表
VX-014K-3A3 OMRON Snap Acting/Limit Switch

获取价格

VX-014K-3C23 OMRON Snap Acting/Limit Switch

获取价格

VX-015-1A3 OMRON Snap Action Switch

获取价格

VX-015-1C23 OMRON Snap Action Switch

获取价格

VX-015-2A3 OMRON Snap Acting/Limit Switch

获取价格

VX-015-2C23 OMRON Snap Acting/Limit Switch

获取价格