Absolute Maximum Ratings
Parameter
Symbol
VCC
Ratings
0 to 6
Unit
V
Power Supply
Input Current
IIN
100
mA
mA
V
Output Current
IOUT
25
Voltage Control Range
Output Select
VC
0 to VCC
0 to VCC
-55 to 125
260 / 40
OSelect
TSTR
V
Storage Temperature
Soldering Temperature / Duration
C
TPEAK / t P
C / sec
Stresses in excess of the absolute maximum ratings can permanently damage the device. Also, exposure to
these absolute maximum ratings for extended periods may adversely affect device reliability. Functional
operation is not implied at these or any other conditions in excess of those represented in the operational
sections of this datasheet. Permanent damage is also possible if any device input (Vc or OS) draws >100 mA.
Test Circuits & Output Load Configurations
Vc (-3.00V to -0.30V)
+2.0V
+3.3V
0.10 F
0.01 F
0.10 F
0.01 F
H (-0.55V to 0.00V)
OSelect M (-1.90V to -1.40V)
L (-3.30V to -2.75V)
+
-
Vc
OSelect
Gnd
Vcc
Vc
Vcc
1
2
6
5
1
2
6
5
+
-
0.01 F
0.01 F
0.01 F
COutput
Output
OSelect
Vee
COutput
Output
Or
0.01 F
240
3
4
3
4
10K
10K
-1.3V
240
V
DMV
Functional Test: Allows use of standard power supply biasing
configuration. Pull down resistors are used for LV-PECL outputs
and are removed for with LVDS outputs. Since the LVDS outputs
are AC coupled, the output DC levels cannot be measured.
Production Test: DC levels shown for Vee, OSelect,
& Vc are for devices configured for 3.3V operation.
LV-PECL outputs are DC coupled to 50 test
Vee
equipment. LVDS outputs are connected to a digital volt meter, then AC
coupled to the test equipment. The digitial volt meter allows for Mid Level &
Swing measurements.
+3.3V
+3.3V
0.10 F
0.10 F
0.01 F
0.01 F
Vc
OSelect
Gnd
Vcc
Vc
OSelect
Gnd
Vcc
1
2
6
5
1
2
6
5
COutput
Output
Z = 50
Z = 50
COutput Z = 50
100
100
Output
Z = 50
3
4
3
4
240
240
LV-PECL to LV-PECL: For short transmission lengths, the pull
down resistor values shown provide reasonable power
consumption and waveform performance.
LVDS to LVDS: The 100 resistor should be removed if this load is