VI-200, VE-200
Maximum Power Available for VI-2xx-xx[a]
Input
Output
Vout Designators
Low Line
Voltage
Vin
Transient[b]
2
Z
3.3
Y
X
X
U
V
5
0
5.2 5.5 5.8 6.5 7.5 10 12 13.8 15 18.5 24 28 36 40 48 52 72 85 95
75%
Designators
Nom. (Range)
Max Power
X
X
Y
U
V
W
U
U
U
V
V
Y
U
W
X
Y
U
V
W
U
U
U
V
V
X
Y
U
V
W
U
U
U
V
V
Y
U
T
X
Y
V
W
W
U
U
V
W
V
W
V
R
X
X
V
W
W
U
U
V
W
V
W
V
M
X
X
U
V
W
U
U
U
V
U
W
U
1
P
2
N
3
X
X
U
V
W
U
U
U
V
U
W
U
L
X
X
U
V
W
U
U
U
V
U
W
U
J
X
X
U
V
W
U
U
U
V
U
W
U
K
X
X
U
V
W
U
U
U
V
U
W
U
4
X
X
U
V
W
U
U
U
V
U
W
U
H
X
F
X
D
X
B
X
12 (10-20)
24 (10-36)
24 (21-32)
24 (18-36)
36 (21-56)
n/a
n/a
18
n/a
18
36
n/a
45
22
n/a
36
n/a
60
0
V
1
W
2
3
N
4
X
--
U
V
W
U
V
U
V
U
W
U
X
Y
U
V
W
U
U
U
V
V
Y
U
X
X
X
X
X
X
X
X
-- -- -- --
U
V
U
V
U
V
U
V
U
V
U
V
U
V
U
V
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
W
U
U
U
V
U
W
U
-- -- --
48 (42-60)
48 (36-76)
72
U
U
U
V
U
W
U
U
U
U
V
U
U
U
U
-- --
U
U
U
U
n/a
110
n/a
215
n/a
425
72 (55-100)
110 (66-160)
150 (100-200)
150 (100-375)
300 (200-400)
n/a
85[c]
n/a
170[d]
T
5
7
V
Y
U
U
W
U
U
W
U
U
W
U
U
W
U
U
-- -- --
U
6
U
U
[a] For additional output power, “booster” modules are available. (VI-Bxx-xx)
[c] 15 Vout, 200 W models are limited to 90 Vdc
[b] Transient voltage for 1 second.
[d] 15 Vout, 200 W models are limited to 185 Vdc
CONVERTER SPECIFICATIONS
(typical at T = 25°C, nominal line and 75% load, unless otherwise specified)
BP
INPUT SPECIFICATIONS
VI-200 E-Grade
Typ
VI-200 C-, I-, M-Grade
Parameter
Min
Max
Min
Typ
Max
Units
Test Conditions
Inrush charge
120x10-6
120x10-6
200x10-6
Coulombs Nominal line
Input reflected
10%
10%
I
IN
Nominal line, full load
120 Hz, nominal line
2400 Hz, nominal line
ripple current – pp
Vin
Vin
Input ripple rejection
dB
dB
25+20Log
30+20Log
(
)
(
(
)
Vout
Vout
Vin
20+20Log
1.35
)
Vout
No load power dissipation
1.35
2
2
Watts
VI-200 DC-DC Converters
Page 2 of 6
Rev 3.6
vicorpower.com
800 927.9474
08/2014