5秒后页面跳转
VI-ANN-MQ PDF预览

VI-ANN-MQ

更新时间: 2024-01-23 13:33:04
品牌 Logo 应用领域
VICOR 输入元件
页数 文件大小 规格书
5页 192K
描述
Analog Circuit, 1 Func, PACKAGE-9

VI-ANN-MQ 技术参数

是否无铅: 含铅是否Rohs认证: 不符合
生命周期:Active零件包装代码:DMA
包装说明:PACKAGE-9针数:9
Reach Compliance Code:not_compliantHTS代码:8542.39.00.01
风险等级:5.02其他特性:INPUT VOLTAGE RANGE: 42VDC TO 60VDC
模拟集成电路 - 其他类型:ANALOG CIRCUITJESD-30 代码:R-XDMA-P9
JESD-609代码:e0功能数量:1
端子数量:9最高工作温度:100 °C
最低工作温度:-55 °C封装主体材料:UNSPECIFIED
封装形状:RECTANGULAR封装形式:MICROELECTRONIC ASSEMBLY
峰值回流温度(摄氏度):NOT SPECIFIED认证状态:Not Qualified
表面贴装:NO温度等级:OTHER
端子面层:TIN LEAD OVER COPPER端子形式:PIN/PEG
端子位置:DUAL处于峰值回流温度下的最长时间:NOT SPECIFIED
Base Number Matches:1

VI-ANN-MQ 数据手册

 浏览型号VI-ANN-MQ的Datasheet PDF文件第2页浏览型号VI-ANN-MQ的Datasheet PDF文件第3页浏览型号VI-ANN-MQ的Datasheet PDF文件第4页浏览型号VI-ANN-MQ的Datasheet PDF文件第5页 
Data Sheet  
VI-IAM, VE-IAM™  
Input Attenuator Modules  
Features  
VI-IAM Specifications  
(Typical at TBP = 25°C, nominal line, 75% load, unless otherwise specified)  
Inputs: 24, 48 and 300 Vdc  
High surge withstand:  
Input Characteristics  
Bellcore  
British Telecom BTR 2511  
IEC-60801-5  
Parameter  
Min  
Typ  
Max  
Units  
Notes  
24 Vdc modules  
Steady state input  
21  
24  
32  
300  
2500  
100  
38  
Vdc  
Vdc  
–A11– models  
EMI/RFI specifications:  
Per BTNR2571 issue 4  
Ringwave 0.5 µs rise 100 kHz  
Figure 1  
Bellcore TR-TSY-000513  
British Telecom BTR 2511  
FCC Level “A”  
Input spike limit  
Vdcpk  
Vdc  
Input surge limit  
Overvoltage shut down[a]  
Recommended fuse  
24 Vdc modules  
34  
18  
Vdc  
100 ms, automatic recovery  
32 V ACG-20  
EN55022 Level “B”  
20  
Amps  
cULus, CTÜVus  
97% efficiency  
Logic disable  
Expansion output for arrays  
Size: 2.28" x 2.4" x 0.5"  
(57,9 x 61,0 x 12,7)  
CE Marked  
Steady state input  
24  
36  
300  
2500  
100  
42  
Vdc  
Vdc  
–AWW– models  
Per BTNR2571 issue 4  
Ringwave 0.5 µs rise 100 kHz  
Figure 1  
Input spike limit  
Vdcpk  
Vdc  
Input surge limit  
Overvoltage shut down[a]  
Recommended fuse  
48 Vdc modules  
37  
42  
Vdc  
100 ms, automatic recovery  
36 V ACG-20  
20  
Amps  
RoHS Compliant (VE-IAM)  
Steady state input  
60  
300  
2500  
160  
67  
Vdc  
Vdc  
–A33– models  
Product Highlights  
Per BTNR2571 issue 4  
Ringwave 0.5 µs rise 100 kHz  
Figure 1  
Input spike limit  
The Input Attenuator Module (VI-IAM) is  
a component-level, DC input front end  
filter designed to occupy minimum board  
space while providing maximum protection  
for today’s sophisticated electrical systems.  
The VI-IAM, in combination with Vicor  
24, 48 and 300 Vdc input modules,  
provides a highly efficient, high density  
power system with outputs from 1 to 95 Vdc  
and power expandable from 25 to 800 W.  
Your system will benefit from the small  
size, efficiency and inherent reliability of  
Vicor’s component-level converters, while  
meeting the toughest demands of  
Vdcpk  
Vdc  
Input surge limit  
Overvoltage shut down[a]  
Recommended fuse  
48 Vdc modules  
62  
36  
Vdc  
100 ms, automatic recovery  
60 V 3AB-20  
20  
Amps  
Steady state input  
76  
300  
2500  
276  
83  
Vdc  
Vdc  
–ANN– models  
Per BTNR2571 issue 4  
Ringwave 0.5 µs rise 100 kHz  
Figure 1  
Input spike limit  
Vdcpk  
Vdc  
Input surge limit  
Overvoltage shut down[a]  
Recommended fuse  
300 Vdc modules  
77  
Vdc  
100 ms, automatic recovery  
80 V 3AB-20  
20  
Amps  
Steady state input  
200  
400  
1000  
2000  
800  
424  
5
Vdc  
Vdc  
–A66– models  
DM, 2 Joule, IAW IEC-801-5  
CM, 2 Joule, IAW IEC-801-5  
Figure 1  
Input spike limit  
Vdc  
Telecommunications and Industrial  
power applications.  
Input surge limit  
Overvoltage shut down[a]  
Recommended fuse  
All models  
Vdc  
402  
Vdc  
100 ms, automatic recovery  
250 V Bussman PC-Tron  
Amps  
This combination provides compliance  
with the transient requirements of  
Bellcore, British Telecom and IEC  
standards, and meets the EMI/RFI  
No load power dissipation  
Inrush current  
0.5  
1.5  
Watts  
% IIN  
110  
125  
Steady state, lIN 10 ms  
specifications of Bellcore, British Telecom  
and FCC Part 15, Subpart B and EN55022.  
[a]  
The VI-IAM disables downstream converters and clamps the converter input voltage at a safe level.  
Model Selection Chart  
Compatible Products  
Model Number  
VI-A11-CU/VE-A11-CU  
Nominal Input Voltage  
Input Range  
21 – 32 Vdc  
18 – 36 Vdc  
42 – 60 Vdc  
36 – 76 Vdc  
200 – 400 Vdc  
Compatible DC-DC Converter Converter  
• VI-200, VE-200, VI-J00, VE-J00  
(Inputs: 1, W, 3, N and 6)  
• Mega Modules  
24 Vdc  
VI-21x-Cx and VI-J1x-Cx  
VI-2Wx-Cx and VI-JWx-Cx  
VI-23x-Cx and VI-J3x-Cx  
VI-2Nx-Cx and VI-JNx-Cx  
VI-26x-Cx and VI-J6x-Cx  
C–grade  
C–grade  
C–grade  
C–grade  
C–grade  
VI-AWW-CU/VE-AWW-CU  
VI-A33-CQ/VE-A33-CQ  
VI-ANN-CQ/VE-ANN-CQ  
VI-A66-CQ/VE-A66-CQ  
24 Vdc  
48 Vdc  
48 Vdc  
300 Vdc  
(Inputs: 1, W, 3, N and 6)  
For additional information see Section 14  
of the VI-200 & VI-J00 Design Guide.  
Note: For alternative product grades change the “C” in the part number to “E”, “I”, or “M”.  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
VI-IAM Input Attenuator Modules  
Rev. 1.2  
Page 1 of 5  
Set your site on VICOR at www.vicorpower.com  

与VI-ANN-MQ相关器件

型号 品牌 获取价格 描述 数据表
VI-ARM VICOR

获取价格

Autoranging Rectifier Modules Up to 1500 Watts
VI-ARM_17 VICOR

获取价格

Autoranging Rectifier Modules Up to 1500 Watts
VI-ARMB-C11 VICOR

获取价格

AC-DC Regulated Power Supply Module, QUARTER-BRICK PACKAGE-7
VI-ARMB-C12 VICOR

获取价格

AC-DC Regulated Power Supply Module, QUARTE-BRICK PACKAGE-7
VI-ARMB-C21 VICOR

获取价格

ARM™ 自动调节整流模块
VI-ARMB-C212 VICOR

获取价格

Autoranging Rectifier Modules Up to 1500 Watts
VIARMB-C212 VICOR

获取价格

Autoranging Rectifier Modules Up to 1500 Watts
VI-ARMB-C213 VICOR

获取价格

Autoranging Rectifier Modules Up to 1500 Watts
VIARMB-C213 VICOR

获取价格

Autoranging Rectifier Modules Up to 1500 Watts
VI-ARMB-C22 VICOR

获取价格

ARM™ 自动调节整流模块