IR Compliance
Suggested IR Profile
tL
tP
Devices are built using lead free epoxy and can be subjected to
standard lead free IR reflow conditions shown in Table 5. Contact
pads are gold over nickel and lower maximum temperatures can also
be used, such as 220C.
260
RUP
217
200
RDN
Table 5. Reflow Profile
Parameter
PreHeat Time
Symbol
ts
Value
150
25
200 sec Max
3°C/sec Max
150 sec Max
480 sec Max
10 sec Max
60 sec Max
6°C/sec Max
tS
tAMB-P
Ramp Up
RUP
Time above 217°C
Time to Peak Temperature
Time att 226600°°CC
tL
tAMB-P
tP
Reliability
Time at 240°C
tP2
Ramp dowwnn
RDN
Time (sec)
Maximum Ratings, Tape & Reel
Absolute Maximum Ratings and Handling Precautions
Stresses in excess of the absolute maximum ratings can permanently damage the device. Functional operation is not implied or any other
excess of conditions represented in the operational sections of this data sheet. Exposure to absolute maximum ratings for extended
periods may adversely affect device reliability.
Although ESD protection circuitry has been designed into the VCC6, proper precautions should be taken when handling and mounting,
VI employs a Human Body Model and Charged Device Model for ESD susceptibility testing and design evaluation.
ESD thresholds are dependent on the circuit parameters used to define the model. Although no industry standard has been adopted for
the CDM a standard resistance of 1.5kOhms and capacitance of 100pF is widely used and therefor can be used for comparison purposes.
Table 6. Maximum Ratings
Parameter
Symbol
TSTORE
Rating
-55/125
Unit
°C
Storage Temperature
Supply Voltage
-0.5 to 5.0
-0.5 to VDD+0.5
1500
V
Enable Disable Voltage
ESD, Human Body Model
ESD, Charged Device Model
V
V
1000
Table 7. Tape and Reel Information
Tape Dimensions (mm)
Reel Dimensions (mm)
W
F
Do
1.5
Po
4
P1
8
A
B
2
C
D
N
W1
17
W2
21
#/Reel
250
16
7.5
180
13
21
55
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com