300V Input
Module-Specific Operating Specifications (Cont.)
5VOUT, 150W (e.g. S300B5C150BL, V300B5C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S300B5C150BL (enhanced efficiency)
V300B5C150BL (standard efficiency)
Ripple and noise
83.8
80.9
86.5
83
%
Nominal input; 75% load; 25°C
198
6.25
6
248
6.47
9.4
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
6.03
0.02
0.2
No load to full load; nominal input
Load current
0
30
Amps
Amps
Amps
Current limit
30.6
21
34.5
34.5
40.5
40.5
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
8VOUT, 200W (e.g. S300B8C200BL, V300B8C200BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S300B8C200BL (enhanced efficiency)
V300B8C200BL (standard efficiency)
Ripple and noise
84.5
83.2
86.5
84.4
280
9.7
%
Nominal input; 75% load; 25°C
350
10.1
6.5
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
9.36
5.5
0.02
0.2
No load to full load; nominal input
Load current
0
25
Amps
Amps
Amps
Current limit
25.5
17.5
28.8
28.8
33.8
33.8
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
12VOUT, 250W (e.g. S300B12C250BL, V300B12C250BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S300B12C250BL (enhanced efficiency)
V300B12C250BL (standard efficiency)
Ripple and noise
87.3
86.3
89.0
87.3
325
14.3
4
%
Nominal input; 75% load; 25°C
405
14.9
6
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
13.7
0.06
0.3
No load to full load; nominal input
Load current
0
20.83
28.1
28.1
Amps
Amps
Amps
Current limit
21.3
14.6
24
24
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
12VOUT, 150W (e.g. S300B12C150BL, V300B12C150BL)
Parameter
Min
Typ
Max
Unit
Notes
Efficiency
S300B12C150BL (enhanced efficiency)
V300B12C150BL (standard efficiency)
Ripple and noise
86.3
85.4
88.0
86.4
240
14.3
5.7
%
Nominal input; 75% load; 25°C
300
14.9
7
mV
Volts
Watts
%
P-P; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
Output OVP set point
Dissipation, standby
Load regulation
13.7
0.02
0.2
No load to full load; nominal input
Load current
0
12.5
16.9
16.9
Amps
Amps
Amps
Current limit
12.7
8.75
14.4
14.4
Output voltage 95% of nominal
Output voltage <250mV
Short circuit current
300V Mini Family
Page 5 of 14
Rev 10.1