24V Input  
Module Family Electrical Characteristics  
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.  
All temperatures refer to the operating temperature at the center of the baseplate.  
Module Input Specifications  
Parameter  
Min  
Typ  
Max  
36  
Unit  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
Notes  
Operating input voltage  
Input surge withstand  
Undervoltage turn–on  
Undervoltage turn–off  
Overvoltage turn–off/on  
Disabled input current  
18  
24  
50  
<100ms  
17.5  
15.3  
37.8  
17.9  
14.8  
36.3  
39.6  
4.0  
PC pin low  
Module Output Specifications  
Parameter  
Min  
Typ  
Max  
1
Unit  
%
Notes  
Output voltage set point  
Line regulation  
Of nominal output voltage. Nominal input; full load; 25°C  
Low line to high line; full load  
Over operating temperature range  
10 – 100% of full load  
0.02  
0.002  
2
0.20  
0.005  
5
%
Temperature regulation  
Power sharing accuracy  
%/°C  
%
Of nominal output voltage. For trimming below 90%  
of nominal, a minimum load of 10% of maximum  
rated power may be required.  
Programming range  
10  
110  
%
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings  
3.3V  
5V  
6.5V  
8V  
12V  
15V  
24V  
28V  
36V  
48V  
–0.5 to 4.7  
–0.5 to 7.0  
–0.5 to 9.1  
–0.5 to 10.9  
–0.5 to 16.1  
–0.5 to 20.0  
–0.5 to 31.7  
–0.5 to 36.9  
–0.5 to 47.1  
–0.5 to 62.9  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
VDC  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Externally applied  
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,  
please refer to output connections on page 10.  
Thermal Resistance and Capacity  
Parameter  
Min  
Typ  
0.16  
0.14  
8.0  
Max  
Unit  
°C/Watt  
°C/Watt  
°C/Watt  
°C/Watt  
Watt-sec/°C  
Baseplate to sink; flat, greased surface  
Baseplate to sink; thermal pad (P/N 20264)  
Baseplate to ambient  
Baseplate to ambient; 1000LFM  
Thermal capacity  
1.9  
83  
24V Mini Family  
Page 2 of 15  
Rev 5.6  
02/2021  

与V24B28M200BF3相关器件

型号 品牌 描述 获取价格 数据表
V24B28M200BG VICOR DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-9

获取价格

V24B28M200BG2 VICOR DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-9

获取价格

V24B28M200BG3 VICOR DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-9

获取价格

V24B28M200BK VICOR 暂无描述

获取价格

V24B28M200BK2 VICOR DC-DC Converter Module

获取价格

V24B28M200BK3 VICOR DC-DC Converter Module

获取价格