5秒后页面跳转
V24A28E400BK2 PDF预览

V24A28E400BK2

更新时间: 2024-02-12 21:35:38
品牌 Logo 应用领域
VICOR /
页数 文件大小 规格书
15页 848K
描述
DC-DC Regulated Power Supply Module

V24A28E400BK2 技术参数

生命周期:Active包装说明:DFM,
Reach Compliance Code:compliantECCN代码:EAR99
风险等级:5.73Is Samacsys:N
模拟集成电路 - 其他类型:APSM DCDC控制模式:VOLTAGE-MODE
最大输入电压:36 V最小输入电压:18 V
标称输入电压:24 VJESD-30 代码:R-XDFM-P9
最大电网调整率:0.2%最大负载调整率:0.2%
功能数量:1输出次数:1
端子数量:9最高工作温度:100 °C
最低工作温度:-10 °C最大输出电压:30.8 V
最小输出电压:2.8 V标称输出电压:28 V
封装主体材料:UNSPECIFIED封装代码:DFM
封装形状:RECTANGULAR封装形式:MICROELECTRONIC ASSEMBLY
表面贴装:NO技术:HYBRID
温度等级:OTHER端子形式:PIN/PEG
端子位置:DUAL最大总功率输出:400 W
微调/可调输出:YESBase Number Matches:1

V24A28E400BK2 数据手册

 浏览型号V24A28E400BK2的Datasheet PDF文件第1页浏览型号V24A28E400BK2的Datasheet PDF文件第2页浏览型号V24A28E400BK2的Datasheet PDF文件第4页浏览型号V24A28E400BK2的Datasheet PDF文件第5页浏览型号V24A28E400BK2的Datasheet PDF文件第6页浏览型号V24A28E400BK2的Datasheet PDF文件第7页 
24V Input  
Module Family Electrical Characteristics (Cont.)  
MODULE CONTROL SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Primary Side (PC = Primary Control; PR = Parallel)  
PC bias voltage  
current limit  
5.50  
1.5  
5.75  
2.1  
6.00  
VDC  
PC current = 1.0mA  
PC voltage = 5.5V  
During normal operation  
3.0  
2.9  
7
mA  
PC module disable  
PC module enable delay  
PC module alarm  
2.3  
2.6  
4
VDC  
ms  
Switch must be able to sink 4mA. See Fig. 2  
0.5  
1.1  
6.1  
Vavg  
MΩ  
Volts  
mA  
Ω
UV, OV, OT, module fault. See Figs. 3 and 5  
See Fig. 3, converter off or fault mode  
PR load >30Ω, <30pF  
PC resistance  
0.9  
5.7  
150  
375  
2.4  
1.0  
5.9  
PR emitter amplitude  
PR emitter current  
PR receiver impedance  
PR receiver threshold  
PR drive capability  
500  
2.5  
625  
2.6  
12  
25°C  
Volts  
Minimum pulse width: 20ns  
Without PR buffer amplifier  
modules  
Secondary Side (SC = Secondary Control)  
SC bandgap voltage  
SC resistance  
1.21  
990  
1.23  
1000  
0.033  
1.25  
VDC  
Ω
Referenced to –Sense  
1010  
SC capacitance  
µF  
SC module alarm  
0
VDC  
With open trim; referenced to –Sense. See Fig. 7  
MODULE GENERAL SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Remote sense (total drop)  
0.5  
VDC  
0.25V per leg (sense leads must be connected to  
respective, output terminals)  
Isolation test voltage (IN to OUT)*  
Isolation test voltage (IN to base)*  
Isolation test voltage (OUT to base)*  
3000  
1500  
500  
VRMS  
VRMS  
VRMS  
Complies with reinforced insulation requirements  
Complies with basic insulation requirements  
Complies with operational insulation requirements  
Isolation resistance  
10  
MΩ  
IN to OUT, IN to baseplate, OUT to baseplate  
6.5  
7.3  
8.1  
ounces  
(grams)  
Weight (E, C, T grade)  
(184.3)  
(207.5)  
(230.7)  
7.4  
8.2  
9.0  
ounces  
(grams)  
Weight (H, M grade)  
(209.3)  
(232.5)  
(255.7)  
Temperature limiting  
Agency approvals  
100  
115  
°C  
See Figs. 3 and 5. Do not operate coverter >100°C.  
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.  
With appropriate fuse in series with the +Input  
cURus, cTÜVus, CE  
* Isolation test voltage, 1 minute or less.  
Note: Specifications are subject to change without notice.  
24V Maxi Family  
Page 3 of 15  
Rev 6.7  
02/2017  
vicorpower.com  
800 927.9474  

与V24A28E400BK2相关器件

型号 品牌 描述 获取价格 数据表
V24A28E400BK3 VICOR DC-DC Converter Module

获取价格

V24A28E400BL VICOR DC-DC Regulated Power Supply Module, 1 Output, 400W, Hybrid, MODULE-9

获取价格

V24A28E400BL2 VICOR CONVERTER MOD DC/DC 28V 400W

获取价格

V24A28E400BL3 VICOR DC-DC Regulated Power Supply Module, 1 Output, 400W, Hybrid, MODULE-9

获取价格

V24A28E400BN VICOR DC-DC Regulated Power Supply Module, 1 Output, 400W, Hybrid, MODULE-9

获取价格

V24A28E400BN2 VICOR DC DC CONVERTER 28V 400W