Input Specifications
Input Current
- At no load
3 mA typ.
Recommended Input Fuse
3.3 Vout models: 800 mA (slow blow)
5 Vout models: 800 mA (slow blow)
6.5 Vout models: 1'000 mA (slow blow)
9 Vout models: 1'000 mA (slow blow)
12 Vout models: 1'000 mA (slow blow)
15 Vout models: 1'000 mA (slow blow)
24 Vout models: 800 mA (slow blow)
www.tracopower.com/overview/tsr0-6wi
See application note:
Input Filter
(Recommended external input filter proposal)
Output Specifications
Voltage Set Accuracy
±2.5% max.
0.9% max.
0.6% max.
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (10 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
3.3 Vout models: 50 mVp-p typ.
5 Vout models: 50 mVp-p typ.
6.5 Vout models: 50 mVp-p typ.
9 Vout models: 50 mVp-p typ.
12 Vout models: 50 mVp-p typ.
15 Vout models: 50 mVp-p typ.
24 Vout models: 75 mVp-p typ.
100 µF max.
Capacitive Load
Minimum Load
Not required
Temperature Coefficient
Start-up Time
±0.02 %/K max.
50 ms typ. (24 Vout model)
25 ms typ. (other models))
Continuous, Automatic recovery
200% typ. of Iout max.
180 mV max. (50% Load Step)
200 µs typ. (50% Load Step)
Short Circuit Protection
Output Current Limitation
Transient Response
- Peak Variation
- Response Time
General Specifications
Relative Humidity
95% max. (non condensing)
–40°C to +85°C
Temperature Ranges
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
+105°C max.
–55°C to +125°C
3.57 %/K above 77°C
165°C typ. (Automatic recovery)
Power Derating
Over Temperature
Protection Switch Off
Cooling System
Natural convection (20 LFM)
117 - 243 kHz (PWM) (3.3 Vout model)
130 - 270 kHz (PWM) (5 Vout model)
163 - 338 kHz (PWM) (6.5 Vout model)
195 - 405 kHz (PWM) (9 Vout model)
247 - 513 kHz (PWM) (12 Vout model)
293 - 608 kHz (PWM) (15 Vout model)
416 - 864 kHz (PWM) (24 Vout model)
Non-isolated
Switching Frequency
Insulation System
Reliability
Environment
- Calculated MTBF
- Vibration
18'160'000 h (MIL-HDBK-217F, ground benign)
MIL-STD-810F
- Mechanical Shock
- Thermal Shock
MIL-STD-810F
MIL-STD-810F
Housing Material
Non-conductive Plastic
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com August 14, 2019
Page 2 / 4