TQM8M9079
500−2700 MHz Variable Gain Amplifier
Absolute Maximum Ratings
Recommended Operating Conditions
Parameter
Rating
Parameter
Min Typ Max Units
Storage Temperature
−65 to 150°C
Control Voltage (VCTRL
)
0.5
5
V
RF Input Power, CW, 50Ω, T = 25°C +24 dBm
Operating Temp. Range
−40
+85
170
°C
°C
Amplifier Voltage (VDEV1,2
)
+4.5 V
+6 V
TJ (for >106 hours MTTF)
Control Voltage (VCTRL
)
Electrical specifications are measured under test conditions as
described or noted. Electrical specifications are not guaranteed
over all recommended operating conditions.
Operation of this device outside the parameter ranges
given above may cause permanent damage.
Electrical Specifications
Test conditions unless otherwise noted: VCC=+5V, RBIAS=24Ω, Maximum gain setting, Temp.=+25°C
Parameter
Conditions
Min
500
Typ
Max
2700
Units
MHz
MHz
dB
Operational Frequency Range
Test Frequency
Gain
2140
38
35
25
Gain Variation Range
Input Return Loss
Output Return Loss
Output IP3
Note 1
30
dB
11
dB
20
dB
Pout=0 dBm/tone, Δf=1 MHz
+25
77
+29
+16
4.0
95
dBm
dBm
dB
Output P1dB
Noise Figure
Amplifier Current
VVA Current (Pin 8)
Thermal Resistance, θJC
Notes:
Note 2
117
61
mA
Note 3
3.6
mA
Junction to backside paddle
°C/W
1. The Gain variation range is measured as the difference in gain with VCTRL = 5 V and VCTRL = 0 V.
2. Amp1 current (pin 3) and Amp2 current (pin 15) are typically 47.5 mA in each
3. VVA typical current is < 1 mA for min attenuation and 3.6 mA for max attenuation
Datasheet: Rev D 07-17-13
Disclaimer: Subject to change without notice
- 2 of 8 -
© 2013 TriQuint
www.triquint.com