TP15AS Series
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Isolation voltage
Seismic
Input / Output 1 minute, leakage current 2mA
3000
VAC
G
10~55Hz
5
Over-current protection
Cooling
Full input range
Burp,
Automatic recovery
Free air convection
Case material
Flame-retardant plastic
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
165
85
Typ.
220
220
Max.
265
265
Units
VAC
VAC
ms
220VAC In module(165V-265V)
220VAC In module(85V-265V)
Non-capacitive load
Startup voltage
Startup voltage
Start rising time
20
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
±3
Units
%
%
%
Voltage accuracy
Io=0.1…1.0 x Ionom Vi=Vi rated
±5
Line regulation
Load regulation
Vimin≤Vi≤Vimax
±0.5
±1
Io=0.1…1.0 x Ionom Vimin≤ Vi≤Vimax
%
Main Load and auxiliary load differ 25%,the auxiliary circuit
of the load with at least 25%, the main circuit with the full
load
Auxiliary voltage accuracy
±3
±1
%
Ripple and noise
20MHz bandwidth
Vimin≤Vi≤Vimax
Vimin≤Vi≤Vimax
%
%
Over-current protection
Switch frequency
120
100
Hz
ENVIRONMENT CHARACTERISTICS
Parameter
Conditions
Min.
-40
Typ.
Max.
+70
+95
+105
90
Units
℃
Operating temperature
Maximum case temperature
Storage temperature
Relative humidity
industrial-class
industrial-class
Industry-class
No condensation
℃
-40
5
℃
RH(%
)
Temperature coefficient
±0.02
%/℃
Case temperature shall not exceed the maximum case temperature
www.gztoppower.con
TEL:020-82019000
Email:sales@gztoppower.com
page 2 of 4