AC/DC Power Supplies
TOP-200 Series
200 Watt
General Specifications
Humidity (non condensing)
Efficiency
0 – 95 % rel. H max.
– Vin = 115 VAC
– Vin = 230 VAC
12 & 15 VDC models: 88 – 91 %
24 & 48 VDC models: 90 – 93 %
12 & 15 VDC models: 90 – 93 %
24 & 48 VDC models: 92 – 95 %
Switching frequency
Hold-up time
100 kHz typ. (pulse width modulation)
10 ms typ.
Start-up time
– Vin = 115 VAC
– Vin = 230 VAC
<3.0s
<2.0s
Remote On/Off
Isolation voltage
– On:
– Off:
open contacts on J3
see J3 remote On/Off function on last page
– Input / Output
– Input / Field Ground
– Output / Field Ground
3000 VAC
1500 VAC
500 VAC
Isolation resistance (at 500 VDC)
Earth leakage current
100 Mohm min.
500 µA max.
Reliability, calculated MTBF at +25°C acc. to IEC 61709
Safety class (for built in use only)
www.tracopower.com/overview/top200
class I, class II prepared with second fuse
Electromagnetic compatibility – Conducted input RI suppression
(EMC), emissions
EN 55022, class B (conductive plane to be
connected to field ground)
– Harmonic current emissions
IEC/EN 61000-3-2, class A
Electromagnets compatibility – RF field immunity
IEC/EN 61000-4-3, 20V/m criteria A
IEC/EN 61000-4-4, 2kV criteria B
IEC/EN 61000-4-5, 1kV/ 2kV criteria B
IEC/EN 61000-4-6, 10V criteria A
IEC/EN 61000-4-8, 100A/m criteria A
IEC/EN 61000-4-11
(EMC), immunity
– Electrical fast transients/burst immunity
– Surge
– Conducted RF
– Magnetic field
– Voltage dip
– Voltage Sag immunity
Semi F47-0706
Safety approvals and
Certification
UL 60950-1, 2nd Ed + AM1
CSA 60950-1-07-2nd Ed
IEC 60950-1:2005 (2nd Edition)
EN 60950-1:2006 + Am 1:2010 + Am
11:2009 + Am 12:2011
Certification documents: www.tracopower.com/overview/top200
Environment
– Vibration acc. IEC 60068-2-6;
– Shock acc. IEC 60068-2-27
3 axis, sine sweep, 10 – 55Hz, 0.075 mm
3 axis, 15g half sine, 11ms
Environmental compliance
– Reach
– RoHS
www.tracopower.com/info/reach-declaration.pdf
RoHS directive 2011/65/EU
Connection
Weight
pin connector (Molex)
315 g (8.93 oz)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com