120 WATT MEDICAL POWER ADAPTERS

TMP120-19 数据手册

 浏览型号TMP120-19的Datasheet PDF文件第2页 
TRUMPower  
120 WATT MEDICAL POWER ADAPTERS  
DESCRIPTION  
(LVD)  
TMP120 SERIES  
Class I, Class II  
The TMP120 series of AC/DC switching power  
adapters are for 96 to 120 watts of continuous  
output power. They are enclosed in a 94V-1 rated  
case with an IEC 320/C14 or C18 inlet to mate with  
interchangeable AC power cord for world-wide  
use. All models meet CISPR 11 and FCC class B  
emission limits, and are designed for medical  
applications.  
RoHS  
FEATURES  
Low safety ground leakage current  
Optional output connectors  
100% burn-in  
Safety Standard Approvals:  
90 to 264VAC wide input range  
Overvoltage and overcurrent protections  
Optional IEC 320/C18 inlet with class II insulation  
Compliant with CEC and Energy Star efficiency  
level IV requirements  
UL 60601-1  
CSA C22.2 No. 601.1  
No load power consumption less than 0.5W  
Average active efficiency 85%  
Compliant with RoHS requirements  
TÜV EN60601-1  
INPUT SPECIFICATIONS  
GENERAL SPECIFICATIONS  
Switching frequency50KHz ~ 110KHz  
Input voltage:  
90 to 264VAC  
Power factor:  
Efficiency:  
Hold-up time:  
Line regulation:  
0.98 typical at 115VAC  
85% min.  
Input frequency:  
Input current:  
47 to 63Hz  
1.60A (rms) for 115 VAC  
0.80A (rms) for 230 VAC  
15 msec minimum at 115VAC  
±0.5% maximum at full load  
90µA max. @ 115 VAC/60Hz  
150µA max. @ 230 VAC/50Hz  
Earth leakage current:  
(Class I)  
Enclosure leakage current:  
(Class II)  
Inrush current:  
60 amps @ 115VAC or 90 amps  
@230VAC, at 25ºC cold start  
4000VAC from input to output  
1500VAC from input to ground  
500VAC from output to ground  
150,000 hours minimum at full load at  
25ºC ambient, calculated per  
MIL-HDBK-217F  
90µA max. @ 264 VAC/50Hz  
Withstand voltage:  
OUTPUT SPECIFICATIONS  
MTBF:  
Output voltage/current:  
Total output power:  
Ripple and noise:  
See rating chart  
120 watts maximum  
2% peak to peak maximum  
Provided on output #1 only;  
set at 112 -140% of its nominal  
output voltage  
EMC Performance (EN60601-1-2: 2001)  
Overvoltage protection:  
EN55011:  
FCC:  
VCCI:  
EN61000-3-2:  
EN61000-3-3:  
EN61000-4-2:  
Class B conducted, Class B radiated  
Class B conducted, Class B radiated  
Class B conducted, Class B radiated  
Harmonic distortion, Class A and D  
Line flicker  
Overcurrent protection:  
All outputs protected to short  
circuit conditions  
Temperature coefficientAll outputs ±0.04%/ºC maximum  
ESD, ±8KV air and ±6KV contact  
Transient response:  
Maximum excursion of 4% or  
better on all models, recovering  
to 1% of final value within 500µs  
after a 25% step load change  
EN61000-4-3:  
EN61000-4-4:  
EN61000-4-5:  
EN61000-4-6:  
EN61000-4-8:  
EN61000-4-11:  
Radiated immunity, 3V/m  
Fast transient/burst, ±2KV  
Surge, ±1KV diff, ±2KV com.  
Conducted immunity, 3Vrms  
Magnetic field immunity, 3A/m  
ENVIRONMENTAL SPECIFICATIONS  
Voltage dips, 30% reduction for 500ms,  
60% reduction for 100ms and >95%  
reduction for 10ms  
Operating temperature0ºC to +60ºC  
Storage temperature:  
Relative humidity:  
Derating:  
-40ºC to +85ºC  
5% to 95% non-condensing  
Derate from 100% at +40ºC  
linearly to 50% at +60ºC  
Tumbler Technologies + TRUMPower  
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA  
Phone: 408-988-6616 Fax: 408-988-6622 email: sales@trumpower.com Website: www.TRUMPower.com  

与TMP120-19相关器件

型号 品牌 描述 获取价格 数据表
TMP120-20 TRUMPOWER 120 WATT MEDICAL POWER ADAPTERS

获取价格

TMP120-24 TRUMPOWER 120 WATT MEDICAL POWER ADAPTERS

获取价格

TMP120-30 TRUMPOWER 120 WATT MEDICAL POWER ADAPTERS

获取价格

TMP120-36 TRUMPOWER 120 WATT MEDICAL POWER ADAPTERS

获取价格

TMP120-48 TRUMPOWER 120 WATT MEDICAL POWER ADAPTERS

获取价格

TMP121 BB 1.5C Accurate Digital Temperature Sensor with SPI Interface

获取价格