TMCH
Vishay Polytech
www.vishay.com
PERFORMANCE CHARACTERISTICS
ITEM
CONDITION
POST TEST PERFORMANCE
A, B, C, E cases
P case
Specified
initial value
-55 °C
+85 °C
+125 °C
-55 °C
+85 °C +125 °C
Capacitance
change
-10 ꢀ to
0 ꢀ
0 ꢀ to
+10 ꢀ
0 ꢀ to
+12 ꢀ
-12 ꢀ to 0 ꢀ to
0 ꢀ to
+12 ꢀ
0 ꢀ
+10 ꢀ
4
6
8
4
6
8
5
7
5
7
Dissipation
factor (ꢀ)
Temperature Measure the specified
characteristics characteristics in each stage
10
10
8
10
12
10
12
10
Not more
than
0.005 CV
or 0.25 ꢁA
whichever
is greater
Not more Not more
Not more Not more
than than
0.05 CV 0.062 CV
or 2.5 ꢁA or 3.12 ꢁA
whichever whichever
is greater is greater
than
0.05 CV
than
0.062 CV
Leakage
current
-
-
or 2.5 ꢁA or 3.12 ꢁA
whichever whichever
is greater is greater
Capacitance change
Within 5 ꢀ of initial value
Within 5 ꢀ of initial value
Solder dip: 260 °C 5 °C
Solder
Shall not exceed initial
specified value
Shall not exceed initial
specified value
P, A, B cases: 10 s 1 s
heat
Dissipation factor
C, E cases: 5 s 0.5 s
resistance
Shall not exceed initial
specified value
Shall not exceed initial
specified value
Reflow 260 °C: 10 s 1 s
Leakage current
Capacitance change
Within 5 ꢀ of initial value
Within 10 ꢀ of initial value
Moisture
Shall not exceed 150 ꢀ of initial
specified value
Shall not exceed 200 ꢀ of
initial specified value
Leave at 85 °C and 85 ꢀ RH Dissipation factor
for 1000 h
resistance
no load
Shall not exceed 200 ꢀ of initial
specified value
Shall not exceed 500 ꢀ of
initial specified value
Leakage current
Capacitance change
Within 20 ꢀ of initial value
Within 20 ꢀ of initial value
High
temperature
load
Shall not exceed initial
Shall not exceed initial
specified value
85 °C. The rated voltage is
applied for 2000 h
Dissipation factor
specified value
Shall not exceed 125 ꢀ of initial
specified value
Shall not exceed 125 ꢀ of
initial specified value
Leakage current
Capacitance change
Dissipation factor
Within 20 ꢀ of initial value
Within 20 ꢀ of initial value
High
temperature
no load
Shall not exceed 150 ꢀ of initial
specified value
Shall not exceed 200 ꢀ of
initial specified value
150 °C with no load for
1000 h
Shall not exceed 200 ꢀ of initial
specified value
Shall not exceed 500 ꢀ of
initial specified value
Leakage current
Leave at -55 °C, normal
temperature, 125 °C, and
normal temperature for
30 min., 3 min., 30 min., and
3 min. Repeat this operation
1000 times running.
Capacitance change
Dissipation factor
Within 5 ꢀ of initial value
Within 20 ꢀ of initial value
Shall not exceed initial
specified value
Shall not exceed initial
specified value
Thermal
shock
Shall not exceed 200 ꢀ of initial
specified value
Shall not exceed 200 ꢀ of
initial specified value
Leakage current
Capacitance change
Dissipation factor
Within 5 ꢀ of initial value
Within 12 ꢀ of initial value
Moisture
resistance
load
Leave at 65 °C and 90 ꢀ to
95 ꢀ RH. The rated voltage
applied for 500 h
Shall not exceed 150 ꢀ of initial
specified value
Shall not exceed 200 ꢀ of
initial specified value
Shall not exceed 200 ꢀ of initial
specified value
Shall not exceed 500 ꢀ of
initial specified value
Leakage current
85 °C. The rated voltage is
applied through a protective 0.5 ꢀ / 1000 h
resistor of 1 /V.
Failure
rate
0.5 ꢀ / 1000 h
Note
Test conditions per JIS C5101-1
•
Revision: 26-Oct-17
Document Number: 40182
7
For technical questions, contact: polytech@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000