TL431, TL431A, TL431B
TL432, TL432A, TL432B
SLVS543M –AUGUST 2004–REVISED JULY 2012
www.ti.com
ABSOLUTE MAXIMUM RATINGS(1)
over operating free-air temperature range (unless otherwise noted)
MIN
MAX
37
UNIT
V
VKA
IKA
Cathode voltage(2)
Continuous cathode current range
Reference input current range
Operating virtual junction temperature
Storage temperature range
–100
150
10
mA
mA
°C
II(ref)
TJ
–0.05
150
150
Tstg
–65
°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to ANODE, unless otherwise noted.
PACKAGE THERMAL DATA(1)
PACKAGE
BOARD
θJC
θJA
PDIP (P)
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
57°C/W
259°C/W
39°C/W
46°C/W
9°C/W
85°C/W
87°C/W
97°C/W
95°C/W
52°C/W
206°C/W
206°C/W
140°C/W
149°C/W
SC-70 (DCK)
SOIC (D)
SOP (PS)
SOT-89 (PK)
SOT-23-5 (DBV)
SOT-23-3 (DBZ)
TO-92 (LP)
131°C/W
76°C/W
55°C/W
65°C/W
TSSOP (PW)
(1) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
RECOMMENDED OPERATING CONDITIONS
MIN
Vref
1
MAX
36
UNIT
V
VKA
IKA
Cathode voltage
Cathode current
100
70
mA
TL43xxC
TL43xxI
TL43xxQ
0
TA
Operating free-air temperature
–40
–40
85
°C
125
10