Datasheet TLE 6228 GP
Electrical Characteristics
Parameter and Conditions
Symbol
Values
Unit
VS = 4.8 to 18 V ; Tj = - 40 °C to + 150 °C
(unless otherwise specified)
min
typ
max
1. Power Supply (VS)
Supply current (Outputs ON)
Supply current (Outputs OFF)
VENA = L, VSTBY = H
IS
IS
8
mA
mA
4
Standby current
VSTBY = L
IS
10 µA
32
Operating voltage
VS
4.8
V
2. Power Outputs
ON state resistance Channel 1,2
ID = 1A; VS ‡ 9.5 V
Tj = 25 � C
Tj = 150°C
Tj = 25 � C
Tj = 150°C
ID ‡ 100 mA
RDS(ON)
RDS(ON)
0.23
0.28
0.26
W
W
0.5
ON state resistance Channel 3,4
ID = 1A; VS ‡ 9.5 V
0.4
0.75
Z-Diode clamping voltage (OUT1...4)
VDS(AZ)
IPD
45
10
60
50
V
µA
µA
µs
Pull down current
VSTBY = H, V = L
20
IN
Output leakage current3
Output turn on time 4
Output turn off time 4
Output on fall time 4
Output off rise time 4
VSTBY = L, 0V £ VDS £ 20V
IDlk
5
ID = 1 A
ID = 1 A
ID = 1 A
ID = 1 A
ton
3
3
15
20
10
5
50
60
toff
3
30
tfall
3
30
trise
Overload switch-off delay time 4
Output off status delay time 4
Failure extension Time for Status Report
Input Suppression Time
tDSO
tD
20
60
100
3000
3000
3000
100
500 1200
500 1200
500 1200
tD-failure
tD-IN
tfOL(off)
10
30
Open Load (off) filtering Time 5
3. Digital Inputs (IN1, IN2, IN3, IN4, ENA)
Input low voltage
VINL
VINH
VINHys
IIN
- 0.3
2.0
50
1.0
6.0
V
V
Input high voltage
Input voltage hysteresis 5
200
30
mV
µA
µA
Input pull down current
Enable pull down current
V = 5 V; VS ‡ 6.5 V
10
60
40
IN
VENA = 5 V; VS ‡ 6.5 V
IENA
10
20
4. Digital Status Outputs (ST1 - ST4) Open Drain
Output voltage low
IST = 2 mA
VSTL
ISTH
0.5
2
V
Leakage current high
µA
3 If the output voltage exceeds 35V, this current (zener current of a internal structure) can rise up to 1mA
4 See timing diagram, resistive load condition; VS ‡ 9 V
5 This parameter will not be testet but assured by design
V4.1
Page
2010-07-10
5