TFSDX-XX-XXX-XX-XX.XX-XX-XXX K
REVISION K
.110 2.79
REF
FEP CABLE OPTION
-T: FEP
-NXX OPTION (END 2)
(LEAVE BLANK FOR STANDARD PVC INSULATION)
(ONLY AVAILABLE WITH -D,-DL,-T,-TL,TR)
K
-NUS: NOTCH UP, STRAIGHT
(PIN 1 TO PIN 2)
No OF POSITIONS
(No OF POS x .050[1.27])
+ .120[2.54] REF
-02 THRU -030 (PER ROW)
-05, -07, -10, -15, -20, -25 & -30
AVAILABLE AS STANDARD
-NDS: NOTCH DOWN, STRAIGHT
(PIN 1 TO PIN N-1)
N (SEE TABLE 2)
-NUX: NOTCH UP, CROSSED
(PIN 1 TO PIN 1)
-NDX: NOTCH DOWN, CROSSED
(PIN 1 TO PIN N)
02
.153 3.89
REF
C
L
(ALL OTHER SIZES AVAILABLE AS ASO)
WIRE GAUGE (AWG)
-28, -30
COLOR CODE
.240 6.10
REF
.225 5.72
REF
END OPTION
LEAVE BLANK FOR ALL BLACK WIRE,
C: COLOR CODED WIRE, SEE COLOR
SEQUENCE TABLE, SHEET 2
-S: SINGLE END (USE DWLX-09-XX-S-XX.XX-XX)
*
** -SL: SINGLE END WITH FRICTION LOCK
***
01
N-1 (SEE TABLE 2)
(USE DWLX-09-XX-S-XX.XX-XX)(SEE SHEET 2, FIG. 4)
** -D: DOUBLE END (USE DWLX-09-XX-D-XX.XX-XX)
(SEE SHEET 2, FIG. 2)
(NOT AVAILABLE WITH FEP OPTION)
.375 9.53
REF
.050 1.27
REF
PLATING SPECIFICATION
-H: HEAVY GOLD (USE DWLX-09-XX-X-XX.XX-H)
-G: LIGHT GOLD (USE DWLX-09-XX-X-XX.XX-G)
-GF: FLASH GOLD (USE DWLX-09-XX-X-XX.XX-GF)
** -T: TRANSFER END (USE DWLX-09-XX-T-XX.XX-XX)
(SEE SHEET 2, FIG. 3 AND SHEET 4)
*
** -DL: DOUBLE END WITH FRICTION LOCK
***
FIG. 1
(USE DWLX-09-XX-D-XX.XX-XX)
(SEE SHEET 2, FIG. 5)
TFSD-XX-D-S
-S: SINGLE END
"A"
(TFSDX-07-28-XX-XX.XX-S SHOWN)
*
** -TL: TRANSFER END WITH FRICTION LOCK
***
(USE DWLX-09-XX-T-XX.XX-XX)
(SEE SHEET 2, FIG. 6)
K ** -TR: TRANSFER END W/RETENTION LATCH(SEE
SHEET 5)(USE DWLX-09-XX-T-XX.XX-XX)(MUST
CHOOSE FROM -NXX OPTIONS)(ONLY
AVAILABLE IN -05 THRU -30 POS)
.562 14.26
REF
.238 6.05
REF
ASSEMBLED LENGTH
SPECIFY IN INCHES [USE DWLX-09-XX-X-XX.XX-XX]
(SINGLE END: 03.00 INCH [76.2mm] MINIMUM,
DOUBLE END: 03.25 INCH [82.6mm] MINIMUM)
* NOT RELEASED FOR PRODUCTION
** MUST CHOOSE FROM -NXX OPTIONS
*** ONLY AVAILABLE ON POS 5, 7, & 10 - 30
C1
XX.XX
(SEE NOTE 12)
DWLX-09-XX-XX-S-XX.XX-XX
K
NOTES:
SECTION "A"-"A"
C
1.
REPRESENTS A CRITICAL DIMENSION.
"A"
2. MINIMUM PULLOUT FORCE: 3 LBS [13.3 N].
3. CONTACT MUST BE INSERTED UNTIL
RETENTION FEATURE LOCKS INTO PLACE.
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
C7
C8
4. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING HI-POT TEST AT 300 V.
AFTER FINAL ELECTRICAL TEST, LABEL EACH ASSEMBLY WITH 1 LABEL-ET.
5. TINNED COPPER WIRE IS RoHS COMPLIANT.
DECIMALS
ANGLES
2
6. PARTS TO BE LAYER PACKAGED.
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail: info@SAMTEC.com code: 55322
.XXX: .005 [.13]
7. END OF DISCRETE WIRE MUST BE IN THE RANGE AFTER CRIMP.
.XXXX: .0020 [.051]
K
8. FOR CRIMP DIMENSIONS SEE DWL-09-XXX-X-XX.XX-XX FOR
SHEET SCALE: 2:1
DO NOT SCALE DRAWING
DESCRIPTION:
PVC APPLICATIONS OR DWLT-09-XX-X-XX.XX-XX-XX FOR FEP APPLICATIONS.
9. NOTE DELETED
MATERIAL:
.050[1.27] SOCKET DISCREET CABLE ASSEMBLY
DWG. NO.
INSULATOR: LCP, COLOR: BLACK
CONTACT: BeCu
CABLE INSULATION: SEE CALLOUT
WIRE: TINNED COPPER
10. END OF DISCRETE WIRE MUST BE IN RANGE AFTER CRIMP.
11. NOTE DELETED.
TFSDX-XX-XXX-XX-XX.XX-XX-XXX
12. FOR LENGTHS LESS THAN 12 IN, TOLERANCE SHALL
BE ±.125[3.18]. FOR OTHER LENGTHS, TOLERANCES SHALL BE ±2%.
BY:
LENNY K
7/18/06
SHEET 1 OF 5
F:\DWG\MISC\MKTG\TFSDX-XX-XXX-XX-XX.XX-XX-XXX-MKT.SLDDRW