tfs125a.doc
Version 1.3
06.01.02
______________________________________________________________________________________________________
VI TELEFILTER
Filter Specification
TFS 125 A - Page 1 / 4
______________________________________________________________________________________________________
Measurement condition
Stability Characteristics and Packing
See page 3
Ambient temperature:
Input power level:
23 °C
0
dBm
Terminating impedances: 50
Ω
Air Reflow Temperature Conditions
See page 4
Construction, pin connection and
recommended land dimensions
See page 2
Characteristics
Remark:
Reference level for the relative attenuation a of the TFS 125 A is the maximum attenuation in the passband. The maximum attenuation in the
rel
pass band is defined as the insertion loss a . The nominal frequency f is fixed at 125 MHz without tolerance or limit. The values of relative
e
N
attenuation a are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is
rel
included in the production tolerance scheme.
D a t a
typ. value
tolerance / limit
______________________________________________________________________________________________________
Insertion loss
a
-
1,5 ... 3,5
dB
e
(Reference level)
______________________________________________________________________________________________________
Nominal frequency 125 MHz
______________________________________________________________________________________________________
1 dB bandwidth min 300 kHz
______________________________________________________________________________________________________
Relative attenuation
f
-
N
BW
-
a
rel
f
-
150 kHz ... f
+150 kHz
28 MHz
-
-
-
-
-
max.
min. 12
min.
1
dB
dB
dB
dB
dB
N
N
N
1
MHz... f
-
f
f
f
-
28 MHz ... f
- 14 MHz
+ 28 MHz
+325 MHz
5
N
N
N
N
+
+
14 MHz... f
28 MHz... f
min. 15
min. 38
N
N
______________________________________________________________________________________________________
VSWR
f
-
150 kHz ... f
+ 150 kHz
______________________________________________________________________________________________________
Absolute group delay
-
max 2 : 1
N
N
GD
f
-
max. 300
ns
N
______________________________________________________________________________________________________
Group delay ripple
150 kHz ... f
GDD
+150 kHz
**)
f
-
-
max 30
ns
N
N
______________________________________________________________________________________________________
Intermodulation
***)
IP3
54
dB
min. 45
dB
______________________________________________________________________________________________________
Input power level max. 10 dBm
______________________________________________________________________________________________________
Temperature coefficient of frequency - 71.6 ppm/K
______________________________________________________________________________________________________
Operating temperature range - 10 °C ... + 85 °C
______________________________________________________________________________________________________
*) ∆f(Hz) = TC (ppm/K) x (∆T) x f (MHz)
TC *)
-
f
f
To
**) measured with smoothing; smoothing aperture ≤ 50 kHz
***) modulation signals: fN and fN + 14 MHz, each of 10 dBm; measured signal: fN - 14 MHz
generated:
checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.