描述
Filter specification

TFS125C_04 数据手册

 浏览型号TFS125C_04的Datasheet PDF文件第2页浏览型号TFS125C_04的Datasheet PDF文件第3页浏览型号TFS125C_04的Datasheet PDF文件第4页浏览型号TFS125C_04的Datasheet PDF文件第5页 
Filename: tfs 125c.doc  
Version 1.3  
15.10.2004  
VI TELEFILTER  
Filter specification  
TFS 125C  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedance: *  
Input:  
23  
0
°C  
dBm  
605 || -11 pF  
620 || -11 pF  
Output:  
Characteristics  
Remark:  
The reference level for the relative attenuation a of the TFS 125C is the maximum attenuation in the pass band. The maximum attenuation in the pass  
rel  
band is defined as the insertion loss a . The nominal frequency fN is fixed at 125,0 MHz without any tolerance or limit. The values of relative attenuation  
e
a
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the  
rel  
production tolerance scheme.  
D a t a  
typ. value  
tolerance / limit  
a
6,5  
-
dB  
max.  
min.  
8
5
dB  
dB  
Insertion loss  
(reference level)  
e
fN  
PB  
-
125,0  
MHz  
Nominal frequency  
Passband  
-
fN  
±
150 kHz  
1,25 dB  
0,80  
dB  
max.  
Pass band ripple  
Relative attenuation  
a
rel  
fN  
fN  
fN  
fN  
fN  
fN  
fN  
±
±
±
±
±
±
+
0,4 MHz ... fN  
0,6 MHz ... fN  
1,2 MHz ... fN  
1,8 MHz ... fN  
3,4 MHz ... fN  
9,5 MHz ... fN  
13,0 MHz ... fN  
±
±
±
±
±
±
+
0,6 MHz  
1,2 MHz  
1,8 MHz  
3,4 MHz  
9,5 MHz  
13,0 MHz  
450,0 MHz  
3,0  
9,5  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
min.  
min.  
min.  
min.  
min.  
min.  
min.  
2
8
dB  
dB  
dB  
dB  
dB  
dB  
dB  
22,5  
20  
25  
30  
43  
55  
30,0  
37,0  
53,0  
60,0  
1,3  
µs  
ns  
max.  
max.  
1,7  
150,0  
µs  
ns  
Absolute group delay within PB  
Group delay ripple within PB  
60,0  
1,4:1  
max.  
min.  
max.  
2,3:1  
VSWR  
**  
80  
-
dB  
60  
10  
dB  
Intermodulation  
Input power level  
dBm  
OTR  
T0  
-
-
- 10 °C ... + 85 °C  
Operating temperature range  
Storage temperature range  
- 40 °C ... + 85 °C  
50  
°C  
-
-
Frequency inversion temperature  
TC ***  
f
-0,032 ppm/K²  
Temperature coefficient of frequency  
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference  
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.  
**) fin1= 111 MHz; fin2= 97 MHz; Pin= 10 dBm fmeasurement = 125 MHz  
***) f (Hz) = Tcf(ppm/K²) x (To - TA) ² x fCAT (MHz)  
c
Generated:  
Checked / Approved:  
Tele Filter GmbH  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

与TFS125C_04相关器件

型号 品牌 获取价格 描述 数据表
TFS125D VECTRON

获取价格

Filter specification
TFS125G VECTRON

获取价格

Filter Specification
TFS125H VECTRON

获取价格

Filter specification
TFS125K VECTRON

获取价格

Filter Specification TFS 125K
TFS125L VECTRON

获取价格

Filter specification
TFS125L-SAW-Filter MICROCHIP

获取价格

Surface Acoustic Wave (SAW) devices are compact, cost competitive radio frequency (RF) sol
TFS125R-SAW-Filter MICROCHIP

获取价格

Surface Acoustic Wave (SAW) devices are compact, cost competitive radio frequency (RF) sol
TFS125S-SAW-Filter MICROCHIP

获取价格

Surface Acoustic Wave (SAW) devices are compact, cost competitive radio frequency (RF) sol
TFS125T-SAW-Filter MICROCHIP

获取价格

Surface Acoustic Wave (SAW) devices are compact, cost competitive radio frequency (RF) sol
TFS125V-SAW-Filter MICROCHIP

获取价格

Surface Acoustic Wave (SAW) devices are compact, cost competitive radio frequency (RF) sol