DC/DC Converters
TEQ 160WIR Series 160 Watt
Output Specifications
Start up time (nominal Vin and constant resistive load)
Transient response (25% load step change)
Output current limitation
75 ms typ. (at power On or remote On)
200 µs typ.
at 120 -150 % of Iout max.
at 115 -130 % of Vout nom.
indefinite, automatic recovery
Over voltage protection
Short circuit protection
Capacitive load
– 48 Vin models
– 72 Vin models
12 VDC models: 10‘800 µF max.
24 VDC models: 2‘700 µF max.
28 VDC models: 1‘900 µF max.
48 VDC models: 660 µF max.
12 VDC models: 12‘500 µF max.
24 VDC models: 3‘100 µF max.
28 VDC models: 2‘300 µF max.
48 VDC models: 790 µF max.
General Specifications
Temperature ranges
– Operating
– Storage
–40°C to +105°C (up to +70°C w/o derating)
–55°C to +105°C
Thermal impedance
Derating
1.45°C/W
See derating graphs page 4 –> TBD
at 120°C
Over temperature protection
Thermal shock
acc. MIL-STD-810F
95 % rel H max.
xxx h –>TBD
Humidity (non condensing)
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign)
Isolation voltage (60sec.)
– Input/Output
– Input/Case
2’250 VDC (basic insulation)
1’600 VDC
Isolation capacitance
Isolation resistance
Switching frequency
Safety standards
Safety approvals
Remote On/Off
– Input/Output
2500 pF max. –> TBD
– Input/Output (500 VDC)
>1 GOhm min.
250 kHz typ. (puls width modulation)
UL 60950-1 , IEC/EN 60950-1
www.ul.com -> certifications -> File e188913
– UL/cUL
– positive logic (standard)
– On: 3 to 12 VDC or open circuit
– Off: 0 to 1.2 VDC or short circuit pin 1 and 3
– On: 0 to 1.2 VDC or short circuit pin 1 and 3
– Off: 3 to 12 VDC or open circuit
3 mA
– negative logic (option -N)
– Off idle current:
Environmental compliance – Reach
www.tracopower.com/products/teq160wir-reach.pdf
RoHS directive 2002/95/EC
– RoHS
Application note: www.tracopower.com/products/teq160wir-application.pdf
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 3 of 5