DC/DC Converters
TEN 60N Series
60 Watt
Input Specifications
Input current at no load
Start-up voltage
10 mA typ.
12 Vin models: < 9.0 VDC
24 Vin models: < 18 VDC
48 Vin models: < 36 VDC
Under voltage shut down (lock-out circuit)
12 Vin models: 8.0 VDC typ.
24 Vin models: 16 VDC typ.
48 Vin models: 32 VDC typ.
Surge voltage (1 sec.)
12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise
EN 55022 class Awith external components
filter proposal to be adviced
ESD (electrostatic discharge)
EN 61000-4-2, air 8 kV, contact 6 kV,
perf. criteria A
Radiated immunity
EN 61000-4-3, 20 V/m, perf. criteria A
Fast transient / surge (with external input capacitor)
EN 61000-4-4, 2 kV, perf. criteria A
EN 61000-4-5, 2 kV perf. criteria A
– external input capacitor
12 & 24 Vin models: Nippon chemi-con KY 220 µF, 100 V, ESR 48 mOhm
and TVS 58V, 3000W peak (SMDJ58A) in parallel
48 Vin models: Nippon chemi-con KY 220 µF, 100 V, ESR 48 mOhm
and TVS 120V, 3000W peak (SMDJ120A) in parallel
Conducted immunity
EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy
1 %
Voltage adjustment range (single output models only)
15 & 24 VDC models: +20%, -10%
other models: 10 %
Regulation
– Input variation Vin min. to Vin max.
– Load variation 0 – 100 %
0.2 % max.
single output models: 0.5 % max.
dual output models: 1 % max.
– Load cross variation 25 % / 100 %
5 % max.
not required
0.02 %/K
Minimum load
Temperature coefficient
Ripple and noise (20 MHz bandwidth)
5.0 VDC: 100 mVp-p max. with 10µF/25V X7R MLCC
12 & 15 VDC: 125 mVp-p max. with 10µF/25V X7R MLCC
24 VDC: 200 mVp-p max. with 4.7µF/50V X7R MLCC
Start up time
(constant resistive load)
– Power On
– Remote On
60 ms typ.
60 ms typ.
Transient response (25% load step change)
Short circuit protection
250 µs typ.
continuous, automatic recovery
150 % of Iout max. typ. hiccup
Over load protection
Over-voltage protection (Zener diode, single output models only)
5 VDC models: 6.2 V
12 VDC models: 15 V
15 VDC models: 20 V
24 VDC models: 30 V
Capacitive load (max. values)
5.0 VDC models: 30’000 µF
12 VDC models: 5850 µF
15 VDC models: 3900 µF
24 VDC models: 2000 µF
12 VDC models: 3900 µF (each output)
15 VDC models: 2400 µF (each output)
24 VDC models: 1000 µF (each output)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 4