TCT Series AL Case
Data Sheet
z Characteristics
Item
Performance
Test conditions (based on JIS C 5101−1 and JIS C 5101−3)
Voltage reduction when temperature exceeds +85°C
Operating Temperature
−55°C to +125°C
+85°C
Maximum operating
temperature with no voltage
derating
Rated voltage (VDC)
Category voltage (VDC)
Surge voltage (VDC)
DC Leakage current
2.5
4
6.3 10 16 20 25 35
at 85°C
at 125°C
at 85°C
1.6 2.5
3.2 5.0
4
8
6.3 10 13 16 22
13 20 26 32 44
Shall be satisfied the voltage on
" Standard list "
As per 4.9 JIS C 5101-1
As per 4.5.1 JIS C 5101-3
Voltage : Rated voltage for 5min
Capacitance tolerance
As per 4.7 JIS C 5101-1
As per 4.5.2 JIS C 5101-3
Shall be satisfied allowance range.
±
20%
Measuring frequency : 120
Measuring voltage : 0.5Vrms +1.5 to 2V.DC
Measuring circuit : DC Equivalent series circuit
±12Hz
Tangent of loss angle
(Df, tan δ)
Shall be satisfied the voltage on
" Standard list "
As per 4.8 JIS C 5101-1
As per 4.5.3 JIS C 5101-3
Measuring frequency : 120
±
12Hz
Measuring voltage : 0.5Vrms +1.5 to 2V.DC
Measuring circuit : DC Equivalent series circuit
As per 4.10 JIS C 5101-1
As per 4.5.4 JIS C 5101-3
Measuring frequency : 100
Impedance
Shall be satisfied the voltage on
" Standard list "
±
10kHz
Measuring voltage : 0.5Vrms or less
Measuring circuit
: DC Equivalent series circuit
Resistance to Appearance There should be no significant abnormality.
As per 4.14 JIS C 5101-1
As per 4.6 JIS C 5101-3
Dip in the solder bath
Soldering heat
The indications should be clear.
L.C.
Less than initial limit
Solder temp
Duration
: 260
: 5±
±5°C
0.5s
Within 20% of initial value
Less than 200% of initial limit
∆C / C
Repetition
: 1
Df (tan δ)
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
Temperature
cycle
Appearance
There should be no significant abnormality.
The indications should be clear.
As per 4.16 JIS C 5101-1
As per 4.10 JIS C 5101-3
Repetition : 5 cycles
(1 cycle : steps 1 to 4) without discontinuation.
L.C.
Less than 200% of initial limit
Within 20% of initial value
Less than 200% of initial limit
∆C / C
Df (tan δ)
Temp.
Time
+
1
2
3
4
−55 3°C
30 3min.
−
Room temp. 3min. or less
+
125 2°C
30 3min.
−
Room temp. 3min. or less
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
Moisture
resistance
Appearance There should be no significant abnormality.
The indications should be clear.
As per 4.22 JIS C 5101-1
As per 4.12 JIS C 5101-3
After leaving the sample under such atmospheric
condition that the temperature and humidity are
60 2°C and 90 to 95% RH, respectiveiy, for 500 12h
leave it at room
temperature for over 24h and then measure the
sample.
L.C.
Less than 200% of initial limit
Within 20% of initial value
∆C / C
Df (tan δ)
Less than 200% of initial limit
www.rohm.com
c
2009.01 - Rev.G
○ 2009 ROHM Co., Ltd. All rights reserved.
3/6